PHY 315 · Electronic Instrumentation I
Our notes
2 min readTypes of error
- Gross errors (blunders): human mistakes: misreading a scale, recording wrongly, wrong range, wrong connections. Avoid by care and repeat readings.
- Systematic errors: of the same size and sign each time.
- Instrumental: calibration error, zero error, wear, friction, loading effects.
- Environmental: temperature, humidity, pressure, magnetic fields.
- Observational: parallax (reading a pointer at an angle).
Reduced by calibration, corrections, careful technique; not reduced by averaging.
- Random errors: small, unpredictable variations (noise, small fluctuations); positive and negative. Reduced by repeating and averaging; treated by statistics.
Statistics of repeated readings
Five readings of a voltage: 10.2, 10.0, 10.1, 9.9, 10.3 V.
- Mean x̄ = 50.5/5 = 10.1 V.
- Deviations: +0.1, −0.1, 0, −0.2, +0.2; their squares sum to 0.10.
- Standard deviation (sample) s = √(0.10/4) ≈ 0.158 V.
- Standard error of the mean = s/√n = 0.158/√5 ≈ 0.071 V.
Result: V = 10.10 ± 0.07 V (one standard error). For a normal distribution about 68% of readings fall within ±s of the mean and about 95% within ±2s.
Averaging more readings reduces the standard error (in proportion to 1/√n), but not systematic errors.
Limiting (guaranteed) errors
Makers state accuracy as limits, often ± a % of full scale. The error as a % of the reading grows as the reading falls.
Example: a 0-150 V voltmeter accurate to ±1% of full scale (±1.5 V). Reading 75 V: error ±1.5/75 = ±2%; reading 30 V: ±5%. Use a range where the reading is near the top of the scale.
Combining errors
For a result Q calculated from measured quantities:
- Sum or difference (Q = A ± B): absolute limiting errors add: δQ = δA + δB.
- Product or quotient (Q = AB or A/B): relative (%) errors add.
- Powers (Q = Aⁿ): relative error × n.
- Limiting (worst-case) errors add directly; for independent random errors use the root sum of squares (RSS), which is more realistic.
Example
Power P = V²/R with V measured to ±1% and R to ±0.5%.
- Limiting error = 2 × 1% + 0.5% = ±2.5%.
- RSS (probable) error = √(2² + 0.5²) % ≈ ±2.06%.
Example (difference of large numbers)
Q = A − B with A = 100 ± 1 and B = 95 ± 1: Q = 5 ± 2, a 40% error, although each reading was about ±1%. Avoid measuring small quantities as the difference of two large ones.
Significant figures
Report a result to a precision that matches its uncertainty: 10.10 ± 0.07 V, not 10.1037 ± 0.07 V.
Exams usually ask
- Classify errors with examples and say how each is reduced.
- Calculate the mean, standard deviation and standard error of readings.
- Find the limiting error of a reading and of a calculated result.
Common mistake
Adding percentage errors for a difference (A − B). For sums and differences add the absolute errors, then convert to a percentage of the result.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Best pick Chemistry 2e, 1.5 Measurement Uncertainty, Accuracy, and Precision
(opens openstax.org in a new tab)
OpenStax, Chemistry 2e, 1.5 Measurement Uncertainty, Accuracy, and Precision, CC BY-NC-SA 4.0 · licence
-
Observational error
(opens en.wikipedia.org in a new tab)
Wikipedia, Observational error, CC BY-SA 4.0 · licence
-
Measurement uncertainty
(opens en.wikipedia.org in a new tab)
Wikipedia, Measurement uncertainty, CC BY-SA 4.0 · licence
Watch
-
Error Analysis Of Control Systems | Error Constant Method | Question 1 | Control Systems
12 min · ≈ 54 MB · about ₦30
(opens youtube.com in a new tab)
-
Instrumentation 05 || Statistical analysis of Random errors
12 min · ≈ 54 MB · about ₦30
(opens youtube.com in a new tab)
-
Instrumentation and Control: Measurement Errors, Noise & Calibration | Systematic vs. Random Errors
28 min · ≈ 126 MB · about ₦71
(opens youtube.com in a new tab)
-
Error Analysis (cont.)
32 min · ≈ 144 MB · about ₦81
(opens youtube.com in a new tab)
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.