The SI system

The International System of Units (SI) has seven base units:

QuantityUnitSymbol
Lengthmetrem
Masskilogramkg
Timeseconds
Electric currentampereA
TemperaturekelvinK
Amount of substancemolemol
Luminous intensitycandelacd

The 2019 redefinition

Since 20 May 2019 all base units are defined by fixing the values of physical constants:

  • The second: from the caesium-133 hyperfine frequency (9,192,631,770 Hz).
  • The metre: from the speed of light, c = 299,792,458 m/s exactly.
  • The kilogram: from the Planck constant, h = 6.626 070 15 × 10⁻³⁴ J s exactly (replacing the platinum-iridium prototype kept in France since 1889).
  • The ampere: from the elementary charge, e = 1.602 176 634 × 10⁻¹⁹ C exactly.
  • The kelvin: from the Boltzmann constant; the mole: from the Avogadro constant.

Anyone with the right apparatus can now realise the units anywhere, without comparison with a single artefact.

Derived units (examples)

QuantityUnitIn base units
Forcenewton Nkg m s⁻²
Energyjoule JN m = kg m² s⁻²
Powerwatt WJ s⁻¹
Chargecoulomb CA s
Voltagevolt VW A⁻¹ = kg m² s⁻³ A⁻¹
Resistanceohm ΩV A⁻¹
Capacitancefarad FC V⁻¹
Pressurepascal PaN m⁻²
Frequencyhertz Hzs⁻¹

Prefixes: G (10⁹), M (10⁶), k (10³), m (10⁻³), μ (10⁻⁶), n (10⁻⁹), p (10⁻¹²).
Non-SI units still used: bar (10⁵ Pa), psi (in the oil industry: 1 psi ≈ 6.895 kPa), °C (T(K) = t(°C) + 273.15), kWh.

Dimensional analysis

Every valid equation must have the same dimensions (M, L, T, I, Θ) on both sides.
Example: check the time constant τ = RC. R has units V/A and C has units C/V = A s/V, so RC has units (V/A)(A s/V) = s ✓.
Dimensional analysis checks formulas, converts units and suggests the form of relations (the Buckingham π method).

Standards and traceability

A hierarchy of standards:

  1. International standards and definitions (the BIPM in Sèvres, France).
  2. Primary (national) standards kept by national metrology institutes.
  3. Secondary standards in calibration laboratories.
  4. Working standards used in laboratories and industry to calibrate everyday instruments.

Traceability: an unbroken chain of calibrations, each with stated uncertainty, linking a measurement back to the national or international standard.
In Nigeria, the Standards Organisation of Nigeria (SON) sets product standards and the National Metrology Institute (under SON, Enugu) and weights and measures services maintain measurement standards; laboratories are accredited (for example under ISO/IEC 17025) so their calibrations are trusted.

Exams usually ask

  • State the SI base units and their 2019 definitions in outline.
  • Express derived units in base units and check equations dimensionally.
  • Explain the hierarchy of standards and traceability.

Common mistake

Writing units as plurals or with wrong capitals (Kg, 5 Kms, mA for megaampere). Symbols are case-sensitive and never take an "s": kg, 5 km, MA.