UNIHIVE

Study Hub UNIPORT PHY 315

PHY 315 · Electronic Instrumentation I

Principles of measurement and control

What measurement is, why we measure, direct and indirect methods, and how measurement feeds control.

Our notes

2 min read

What measurement is

Measurement is the process of comparing an unknown quantity (the measurand) with a standard of the same kind, to express it as a number times a unit: "the temperature is 37.2 °C". Every measurement has an uncertainty.

Why we measure

  1. Monitoring: knowing the state of a process or the environment (a weather station, a patient's temperature, a pipeline's pressure).
  2. Control: feeding a measured value to a controller that adjusts the process (a thermostat, a level controller in a tank, an engine management system).
  3. Experimental analysis: testing theories and designs in research and development.
  4. Trade and safety: fair sales by weight and volume (fuel pumps, weighing scales), and safety limits (gas detectors).

Methods of measurement

  • Direct: compare with a standard directly (a metre rule, a balance).
  • Indirect: measure related quantities and calculate (density from mass and volume; power from voltage and current).
  • Deflection method: the measurand produces a deflection (a moving-coil meter, a spring balance). Quick, but loads the system and is less accurate.
  • Null (balance) method: adjust a known quantity until a detector reads zero (a Wheatstone bridge, a potentiometer, an equal-arm balance). Very accurate, because the detector only needs to sense zero.

Analogue and digital instruments

  • Analogue: a continuously varying output (pointer, voltage).
  • Digital: output in discrete steps (numbers); uses an analogue-to-digital converter. Easier to read, store and send; resolution set by the number of bits (a 12-bit converter on 0-10 V resolves 10/4,096 ≈ 2.4 mV).

From measurement to control

A control system keeps a variable at a desired value (the set point).

  • Open-loop control: the controller acts without measuring the result (a timer-controlled washing machine, a toaster). Simple, but cannot correct disturbances.
  • Closed-loop (feedback) control: the output is measured, compared with the set point, and the error drives the controller (an air conditioner with a thermostat, cruise control, a voltage regulator). It corrects disturbances, but can become unstable if badly designed.

Block diagram of a closed-loop system

Set point → (comparator: error = set point − measured value) → controller → actuator → process → output, with a measuring element (sensor) feeding the output back to the comparator.
The accuracy of a closed-loop system can be no better than its measurement: a thermostat with a sensor reading 2 °C high holds the room 2 °C too cold.

Instrumentation in practice

Process industries (oil and gas, power, chemicals, water), medicine, laboratories (SLT), environmental monitoring, vehicles and consumer devices all rely on instruments. In oil and gas, instrument technicians and engineers calibrate pressure, flow, level and temperature instruments and maintain control systems.

Exams usually ask

  • Define measurement and state its purposes.
  • Compare deflection and null methods with examples.
  • Distinguish open- and closed-loop control with block diagrams.

Common mistake

Thinking a closed-loop controller can make up for a faulty sensor. Feedback holds the measured value at the set point, so any sensor error goes straight into the controlled variable.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All PHY 315 topics

Report

Sign in to report this. It is free.