UNIHIVE

Study Hub UNIPORT PHY 315

PHY 315 · Electronic Instrumentation I

Polar plots and the Nyquist stability criterion

Plotting G(jω) in the complex plane, the Nyquist criterion, and gain and phase margins.

Our notes

2 min read

Polar plots

A polar plot draws G(jω) as a curve in the complex plane as ω goes from 0 to ∞: each point has length |G(jω)| and angle ∠G(jω).

Example: first-order lag

G(jω) = 1/(1 + jωτ).

  • ω = 0: G = 1 (point 1, 0°).
  • ω = 1/τ: G = 1/(1 + j) = 0.5 − j0.5: magnitude 0.707, angle −45°.
  • ω → ∞: G → 0 from the −90° direction.

The plot is a semicircle of radius 0.5 centred at (0.5, 0) in the lower half-plane.
Check at ω = 1/τ: the point (0.5, −0.5) is at distance 0.5 from (0.5, 0) ✓.

Shapes by type

Each extra pole adds up to −90° at high frequency: a third-order lag ends at −270°, crossing the negative real axis on the way; an integrator (1/s) makes the plot start at infinity along −90°.

The Nyquist stability criterion

Tests the stability of the closed loop from the open-loop frequency response GH(jω).
Simplified form (for open-loop systems that are stable, the usual case): the closed-loop system is stable if the polar plot of GH(jω), for ω from 0 to ∞, does not encircle (pass to the left of) the critical point −1 + j0.
General form: Z = N + P, where P is the number of open-loop poles in the right half-plane, N the number of clockwise encirclements of −1 by the full Nyquist plot (ω from −∞ to ∞), and Z the number of closed-loop poles in the right half-plane. Stable when Z = 0.

Why −1?

The closed-loop characteristic equation is 1 + GH = 0, so closed-loop poles occur where GH = −1. If the loop gain at the frequency where the phase is −180° is 1 or more, a signal round the loop returns equal or bigger and in phase: sustained or growing oscillation.

Gain and phase margins

Measures of how far a stable system is from instability:

  • Phase crossover frequency ω_pc: where ∠GH = −180°. Gain margin GM = 1/|GH(jω_pc)| (or −20 log|GH| in dB). GM > 1 (positive dB) means stable.
  • Gain crossover frequency ω_gc: where |GH| = 1 (0 dB). Phase margin PM = 180° + ∠GH(jω_gc). PM > 0 means stable.

Typical design targets: GM of at least about 2 (6 dB) and PM of about 30-60°.

Example

GH(s) = 6/[(s + 1)(s + 2)(s + 3)].

  • The phase is −180° where ω = √11 ≈ 3.32 rad/s (from the Routh-Hurwitz topic).
  • There, |(jω + 1)(jω + 2)(jω + 3)| = 60, so |GH| = 6/60 = 0.1.
  • Gain margin = 1/0.1 = 10 (20 dB): the gain could rise tenfold, to K = 60, before oscillation ✓ (the same limit as the Routh test).

Margins on a Bode plot

The same margins can be read from Bode plots: GM is the distance below 0 dB at the frequency where the phase is −180°; PM is the distance above −180° at the frequency where the magnitude crosses 0 dB.

Exams usually ask

  • Sketch the polar plot of a given transfer function.
  • State the Nyquist stability criterion and apply it.
  • Calculate gain and phase margins.

Common mistake

Applying the simple "does not encircle −1" rule to an open-loop system that is itself unstable. Then the full rule Z = N + P is needed.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All PHY 315 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.