PHY 315 · Electronic Instrumentation I
Our notes
2 min readFrequency response
For a stable linear system with a sinusoidal input x = X sin ωt, the steady output is also a sine wave of the same frequency, with a different amplitude and phase:
y = X |G(jω)| sin(ωt + φ), where |G(jω)| is the amplitude ratio and φ = ∠G(jω) the phase.
Get G(jω) by putting s = jω in the transfer function.
Frequency response shows how faithfully an instrument follows fast signals (vibration, sound, ECG, AC signals) and is used to design control loops.
Decibels
Magnitude in decibels: M (dB) = 20 log₁₀ |G|. A gain of 10 is 20 dB, 100 is 40 dB, 0.707 is −3 dB, 0.1 is −20 dB.
Bode plots
Two graphs against log frequency: magnitude in dB and phase in degrees. Products of factors become sums, so plots of standard factors are added.
Standard factors
| Factor | Magnitude | Phase |
|---|---|---|
| Constant K | flat at 20 log K | 0° |
| Integrator 1/(jω) | −20 dB/decade, 0 dB at ω = 1 | −90° |
| Differentiator jω | +20 dB/decade | +90° |
| First-order lag 1/(1 + jωτ) | 0 dB to the corner frequency ω_c = 1/τ, then −20 dB/decade; −3 dB at ω_c | 0° → −90°, −45° at ω_c |
| First-order lead (1 + jωτ) | mirror image: +20 dB/decade | 0° → +90° |
| Second-order lag | 0 dB then −40 dB/decade above ωₙ; a peak near ωₙ if ζ < 0.707 | 0° → −180°, −90° at ωₙ |
Example
G(s) = 10/(1 + s/100).
- Low frequencies: 20 log 10 = 20 dB, phase 0°.
- Corner at 100 rad/s: 20 − 3 = 17 dB, phase −45°.
- At 1,000 rad/s: about 20 − 20 = 0 dB (asymptote; exact: 20 − 10 log(1 + 100) ≈ −0.04 dB), phase ≈ −84°.
Check exact magnitude at the corner: 10/√2 ≈ 7.07, and 20 log 7.07 ≈ 17.0 dB ✓.
Bandwidth
The frequency at which the magnitude has fallen 3 dB below its low-frequency value. For a first-order system the bandwidth is ω_c = 1/τ (rad/s), or f = 1/(2πτ) Hz. Example: a sensor with τ = 1 ms has a bandwidth of about 159 Hz; it cannot follow signals much faster than this.
Speed and bandwidth go together: rise time ≈ 0.35/f_bw (first order).
Resonance in second-order instruments
For ζ < 0.707 the magnitude peaks near ωₙ: peak = 1/(2ζ√(1 − ζ²)). For ζ = 0.1 the peak is about 5 (14 dB): an accelerometer or pressure sensor driven near resonance gives wrongly large readings. Instruments are used well below their natural frequency, or damped to ζ ≈ 0.7 for the flattest response.
Minimum-phase systems
For systems without right-half-plane zeros or delays, the phase is fixed by the magnitude slope; a pure delay e^(−jωT) adds phase lag ωT without changing magnitude, which is dangerous in control loops.
Exams usually ask
- Find |G(jω)| and ∠G(jω) for a transfer function.
- Sketch Bode asymptotes and phase for combinations of standard factors.
- Find bandwidth and explain resonance in second-order instruments.
Common mistake
Reading the asymptote as the exact value at the corner. At the corner frequency the exact magnitude of a first-order lag is 3 dB below the asymptote.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Frequency response
(opens en.wikipedia.org in a new tab)
Wikipedia, Frequency response, CC BY-SA 4.0 · licence
-
Bode plot
(opens en.wikipedia.org in a new tab)
Wikipedia, Bode plot, CC BY-SA 4.0 · licence
Watch
-
Best pick Electrical Engineering: Ch 15: Frequency Response (18 of 56) Bode Plot: A Simple Example
5 min · ≈ 23 MB · about ₦13
(opens youtube.com in a new tab)
-
Control Bootcamp: Example Frequency Response (Bode Plot) for Spring-Mass-Damper
18 min · ≈ 81 MB · about ₦45
(opens youtube.com in a new tab)
-
Control System Lectures - Bode Plots, Introduction
13 min · ≈ 59 MB · about ₦33
(opens youtube.com in a new tab)
-
Why Use Bode Plots for Designing Control Systems? | Understanding Bode Plots, Part 1
6 min · ≈ 27 MB · about ₦15
(opens youtube.com in a new tab)
-
Bode Plot - Problem 2 - Frequency Response Analysis - Control Systems
33 min · ≈ 149 MB · about ₦84
(opens youtube.com in a new tab)
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.