Steam power generation cycles

The Carnot and Rankine cycles, the T-s diagram, efficiency and work, and the effects of pressure, superheat and condenser pressure.

Our notes

2 min read

The ideal Rankine cycle

The basic cycle of steam power plants:
1-2. Turbine: isentropic expansion of steam, producing work.
2-3. Condenser: constant-pressure heat rejection; steam to saturated liquid.
3-4. Pump: isentropic compression of liquid to boiler pressure.
4-1. Boiler: constant-pressure heat addition to superheated steam.
Per kg of steam:

  • Turbine work w_t = h₁ − h₂
  • Pump work w_p = h₄ − h₃ ≈ v₃(p₄ − p₃)
  • Heat added q_in = h₁ − h₄
  • Thermal efficiency η = (w_t − w_p)/q_in
  • Back work ratio = w_p/w_t (very small for steam: an advantage over gas cycles).
  • Specific steam consumption = 3,600/w_net (kg/kWh).

Why not Carnot?

A Carnot cycle using wet steam would need to compress a wet mixture (hard) and limits heat addition to the two-phase region (low temperature). Rankine is practical.

Worked example: ideal Rankine cycle

Boiler 4 MPa, 400 °C; condenser 10 kPa.

  • State 1 (4 MPa, 400 °C): h₁ = 3,213.6 kJ/kg, s₁ = 6.7690 kJ/(kg·K).
  • State 2 (10 kPa, s₂ = s₁): s_f = 0.6493, s_fg = 7.5009 → x₂ = (6.7690 − 0.6493)/7.5009 = 0.816; h₂ = 191.83 + 0.816 × 2,392.8 = 2,144.1 kJ/kg.
  • State 3: h₃ = 191.83 kJ/kg, v₃ = 0.00101 m³/kg.
  • Pump: w_p = 0.00101 × (4,000 − 10) = 4.03 kJ/kg; h₄ = 195.86 kJ/kg.
  • w_t = 3,213.6 − 2,144.1 = 1,069.5 kJ/kg; q_in = 3,213.6 − 195.86 = 3,017.7 kJ/kg.
  • η = (1,069.5 − 4.03)/3,017.7 = 35.3%. Back work ratio = 0.4%.
  • Steam rate = 3,600/1,065.5 = 3.38 kg/kWh: a 100 MW plant needs about 338 t of steam per hour.

Ways to raise efficiency

Raise the average temperature of heat addition or lower the temperature of heat rejection:

  1. Lower condenser pressure (limited by cooling water temperature; increases wetness at turbine exit).
  2. Superheat to higher temperature (limited by materials, about 540-620 °C; reduces wetness).
  3. Raise boiler pressure (increases wetness unless reheated); supercritical plants above 22.1 MPa reach efficiencies above 40-45%.

Reheat cycle

Steam expands in a high-pressure turbine, returns to the boiler to be reheated, then expands in a low-pressure turbine. Main benefit: drier steam at exit (exit quality should be above about 0.88-0.90 to limit blade erosion), with a small gain in efficiency.

Regenerative cycle

Steam is bled from the turbine to heat feedwater (see the feedwater heaters topic). Raises the average temperature of heat addition: the biggest practical gain; nearly all large plants use several heaters.

Real cycles

Turbine and pump isentropic efficiencies (turbine about 85-90%), pressure drops, heat losses. Actual turbine work = η_t × (h₁ − h₂s).

Exams usually ask

  • Sketch the Rankine cycle on T-s and h-s diagrams.
  • Calculate work, heat, efficiency and steam rate using steam tables.
  • Explain the effect of pressure, superheat, reheat and condenser pressure on efficiency.

Common mistake

Forgetting pump work or using h_g instead of h_f at the condenser exit. The pump takes saturated liquid (h_f).