Why store energy

Electricity demand and supply must balance at every instant. Storage:

  • shifts energy from low-demand to high-demand times (load levelling, peak shaving);
  • smooths variable solar and wind;
  • provides frequency regulation and backup;
  • supports off-grid and mini-grid systems (essential for solar homes in Nigeria).

Key measures

  • Energy capacity (kWh, MWh) and power rating (kW, MW); duration = energy/power.
  • Round-trip efficiency = energy out ÷ energy in.
  • Cycle life, depth of discharge (DoD), energy density (Wh/kg), response time, cost per kWh.

Pumped hydro storage

Pumps water uphill when power is cheap or plentiful; releases it through turbines at peak. The largest share of the world's grid storage. Round-trip efficiency about 70-85%.

Worked example

An upper reservoir holds 1,000,000 m³ at 100 m head: E = ρgVH = 1,000 × 9.81 × 10⁶ × 100 = 9.81 × 10¹¹ J = 272.5 MWh; at 80% efficiency about 218 MWh delivered.

Batteries

TypeNotes
Lead-acidcheap, mature, heavy, short life at deep discharge (use about 50% DoD); common with inverters in Nigerian homes
Lithium-ion (LFP, NMC)high energy density and efficiency (about 90-95%), long cycle life, falling cost; grid batteries, solar systems, electric vehicles
Flow batteries (vanadium)energy and power sized separately; long life
Sodium-sulphur, sodium-iongrid storage, emerging

Worked example: battery sizing

A home needs 3 kWh overnight from a 48 V lithium battery at 80% usable DoD and 95% inverter efficiency: required capacity = 3,000/(0.8 × 0.95) = 3,947 Wh → 82 Ah at 48 V (choose 100 Ah).

Compressed air energy storage (CAES)

Air is compressed into underground caverns and later expanded through turbines (often with fuel heating). Large scale; few plants.

Flywheels

Store kinetic energy E = ½Iω²; very fast response, high power, short duration (seconds to minutes): frequency regulation, UPS.

Thermal storage

Molten salt in CSP plants, hot water and ice storage, steam accumulators in industry.

Hydrogen

Electrolysis of water with surplus electricity; stored and used in fuel cells or turbines. Low round-trip efficiency (about 30-40%) but good for long-term and seasonal storage.

Other

Supercapacitors (very high power, short duration), gravity storage, pumped heat.

Exams usually ask

  • Explain the need for energy storage in power systems.
  • Compare pumped hydro, batteries, CAES and flywheels.
  • Calculate the energy stored in a pumped storage scheme or size a battery bank.

Common mistake

Confusing power and energy ratings. A 1 MW, 4 MWh battery can deliver 1 MW for 4 hours, not 4 MW.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All MEG 508 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.