The source-path-receiver approach

  1. At the source (best): quieter machines, lower speeds, balancing and alignment, better lubrication, flexible couplings, damping treatments on panels, low-noise fans and gears, avoiding impacts, maintenance (worn bearings and loose parts are noisy).
  2. Along the path: enclosures, barriers, absorption, distance, silencers, vibration isolation (structure-borne noise is often the main path).
  3. At the receiver: control rooms and acoustic booths, limiting exposure time (rotation of tasks), hearing protection (earplugs, earmuffs) as the last line of defence.

The hierarchy of controls puts elimination and engineering controls before administrative controls and personal protection.

Sound absorption and reverberation

Indoors, sound reflects from surfaces, building up a reverberant field. Absorbent materials (porous: mineral wool, foam, fibreboard; panel absorbers; perforated panels with backing) reduce it.

  • Absorption coefficient α (0 = reflects all, 1 = absorbs all) depends on frequency.
  • Total absorption A = Σ Sᵢαᵢ (m² sabins).
  • Sabine's reverberation time: T₆₀ = 0.161 V / A.

Example: a workshop of V = 200 m³ with A = 40 m²: T₆₀ = 0.161 × 200/40 = 0.81 s.

  • Increasing absorption from A₁ to A₂ reduces the reverberant level by 10 log(A₂/A₁): doubling absorption gives 3 dB. Absorption helps people away from the source, not the operator standing next to it (direct field).

Sound insulation: transmission loss

Transmission loss TL = 10 log(1/τ), τ the fraction of sound energy transmitted through a wall.
Mass law (single panel, at frequencies above its resonance and below its coincidence frequency):
TL ≈ 20 log₁₀(m′ f) − 47 dB, where m′ is the surface mass (kg/m²).
Example: a 10 kg/m² panel at 500 Hz: 20 log(5,000) − 47 = 27 dB. Doubling the mass or the frequency adds about 6 dB.
Double walls with an air gap and absorbent infill do better than a single wall of the same mass. Gaps and holes ruin insulation: a small opening can cut the TL of a good wall drastically.

Enclosures

Close-fitting or room-sized boxes around machines: heavy outer skin, absorbent lining, sealed joints, silenced ventilation openings, vibration isolation from the machine, access doors that seal. Realistic reductions: 10-30 dB. Generator enclosures ("soundproof" generators) are a common Nigerian example.

Barriers

Walls between source and receiver outdoors or in open plant areas. Effective when they block the line of sight, are high and close to the source or receiver, and have no gaps; 5-15 dB is typical. Low frequencies diffract around barriers more easily.

Silencers (mufflers)

  • Reactive (expansion chambers, resonators): reflect sound back; good for low-frequency tonal noise (engine exhausts).
  • Dissipative (absorbent-lined ducts, splitters): absorb sound over broad frequencies (fans, ventilation).
  • Active noise control: loudspeakers produce anti-phase sound, effective for low frequencies in ducts and headphones.

Vibration damping treatments

Thin panels radiate noise when they vibrate; add damping layers (free-layer or constrained-layer viscoelastic materials) or stiffen and isolate them.

Hearing protection

Choose by the required attenuation (manufacturer's rating, de-rated for real use), comfort and the need to hear warnings. Hearing conservation programmes include noise surveys, engineering controls, audiometric testing and training.

Exams usually ask

  • Explain source, path and receiver control with examples.
  • Use Sabine's formula and the mass law.
  • Design principles of enclosures, barriers and silencers.

Common mistake

Lining a room with absorbent and expecting the machine operator's exposure to fall a lot. Absorption reduces the reverberant field, but the operator near the machine is mostly in the direct field.