UNIHIVE

Study Hub UNIPORT MEG 505

MEG 505 · Mechanical Vibration and Noise

Vibration measurement, monitoring and computer-aided analysis

Transducers, signal processing and FFT, vibration severity, condition monitoring, experimental modal analysis, finite elements and software for vibration and noise.

Our notes

3 min read

Transducers

  • Accelerometers (piezoelectric; MEMS in cheaper devices): the most common; wide frequency range; mounting by stud, adhesive or magnet affects the usable upper frequency.
  • Velocity transducers (seismic coil type) and proximity probes (eddy-current, non-contact) for shaft displacement in journal bearings.
  • Laser vibrometers: non-contact velocity.
  • Microphones and sound level meters (Class 1 and Class 2), sound intensity probes for source location.
  • Impact hammers and shakers to excite structures.

Relations between displacement, velocity and acceleration

For harmonic motion at frequency f: v = ωx, a = ω²x.
Example: 0.1 mm peak displacement at 50 Hz: v = 2π × 50 × 0.1 = 31.4 mm/s peak (22.2 mm/s RMS); a = (2π × 50)² × 0.0001 = 9.87 m/s² (about 1 g).
(Checked by computer.)
Displacement emphasises low frequencies, acceleration high frequencies, velocity is a good middle measure of vibration severity.

Signal processing

  • Sampling and anti-aliasing filters: sample at more than twice the highest frequency of interest (Nyquist).
  • FFT spectrum analysis: turns time signals into frequency spectra, where peaks identify causes.
  • Windowing (Hanning for continuous signals) to reduce leakage; averaging to reduce noise.
  • Frequency response functions (FRFs) from force and response measurements; coherence checks quality.
  • Order tracking for machines changing speed; envelope analysis for rolling-bearing defects.

Vibration severity and condition monitoring

Standards (ISO 10816 and its replacement ISO 20816 series) give zones of acceptable RMS velocity for machine classes. Trends over time matter more than single readings.
Common faults and their spectral signs:

FaultTypical sign
unbalancehigh 1× running speed, radial, in phase
misalignmenthigh 2× (and 1×), high axial vibration
loosenessmany harmonics of running speed
rolling bearing defectsbearing defect frequencies, high-frequency envelope
gear faultsgear mesh frequency with sidebands
electrical faults2× line frequency (100 Hz in Nigeria)
resonancea peak that moves with structure, not with speed

Predictive maintenance with vibration monitoring is widely used on pumps, compressors and turbines in Nigerian oil, gas and power plants, saving unplanned shutdowns.

Experimental modal analysis

Excite with a hammer or shaker at several points, measure FRFs, and fit them (curve fitting) to obtain natural frequencies, damping ratios and mode shapes. Used to validate finite element models and to troubleshoot resonances.

Computer-aided analysis

  • Finite element method (FEM): mesh the structure, assemble [M] and [K], solve the eigenvalue problem for modes, then harmonic, transient or random response. Software: ANSYS, Abaqus, NASTRAN, COMSOL, SolidWorks Simulation, and free tools such as Code_Aster and CalculiX.
  • Rotor dynamics software for critical speeds and stability of rotors and bearings.
  • Multibody dynamics (ADAMS, Simscape) for mechanisms and vehicles.
  • Acoustics: boundary element and finite element acoustics, and ray-tracing room acoustics; environmental noise mapping (ISO 9613-based software).
  • Programming: MATLAB, Octave, Python (NumPy, SciPy) or Scilab to solve equations of motion, eigenproblems and FFTs: e.g. scipy.linalg.eigh(K, M) gives natural frequencies and modes of an MDOF model.
  • Control design: active vibration control and active noise control simulations.

Always check models with hand calculations and test data: wrong boundary conditions or units are the commonest causes of wrong results.

Exams usually ask

  • Choose transducers for given measurements; convert between displacement, velocity and acceleration.
  • Diagnose faults from vibration spectra.
  • Describe the steps of experimental modal analysis and of FEM vibration analysis.

Common mistake

Trusting a computer model without validation. A finite element model must be checked against simple calculations and, where possible, measured natural frequencies.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.