UNIHIVE

Study Hub UNIPORT MEG 502

MEG 502 · Control Engineering

Control system components

Potentiometers, synchros and resolvers, encoders, tachogenerators, DC and AC servomotors, actuators and typical control loops.

Our notes

2 min read

Error detectors and position sensors

  • Potentiometer: a voltage proportional to shaft angle: V = K_p θ (K_p = supply voltage ÷ total angle). Two potentiometers in a bridge give an error voltage proportional to θ_r − θ_c.
  • Synchro transmitter-control transformer pair: an a.c. error signal proportional to the sine of the angle difference; robust, used in older radar and ship systems.
  • Resolver: gives sine and cosine of the shaft angle; rugged; used in robots and electric vehicles.
  • Optical encoders: incremental (pulses per revolution; counting gives position, pulse rate gives speed) and absolute (a unique code for each position, keeps position after power loss).
  • LVDT (linear variable differential transformer): linear position.

Speed sensors

  • DC tachogenerator: output voltage proportional to speed: V = K_t ω. Used for velocity feedback.
  • AC tachogenerators, encoders, Hall-effect sensors.

Worked example: potentiometer and tacho

A single-turn potentiometer on 10 V over 350° of travel: K_p = 10 ÷ 350 = 0.0286 V/degree (1.64 V/rad). A tachogenerator rated 7 V per 1,000 rpm: at 1,500 rpm it gives 10.5 V; in SI units K_t = 7 ÷ (1,000 × 2π/60) = 0.0668 V s/rad.

Actuators

  • DC servomotors (armature or field controlled), brushless DC and AC servomotors, stepper motors (open-loop positioning by steps: a 1.8° stepper has 200 steps per revolution).
  • Hydraulic and pneumatic cylinders and motors (large forces).
  • Control valves (process flow), solenoids, relays and contactors, heaters.

Amplifiers and controllers

Power amplifiers (PWM drives, servo drives), op-amp controllers, PLCs and microcontrollers.

Typical loops

LoopSensorActuator
Position control of a DC motorpotentiometer or encoderDC motor and amplifier
Speed control of a DC motortachogenerator or encodermotor drive
Temperature controlthermocouple, RTDheater (relay or thyristor)
Liquid level controlfloat, pressure sensorcontrol valve or pump
Alternator voltage controlvoltage transformerfield current (automatic voltage regulator)

Worked example: position servo

Potentiometer error detector K_p = 1.6 V/rad, amplifier gain K_a = 20, motor and load G_m(s) = 2 ÷ (s(0.5s + 1)) (rad per volt), unity feedback.

  • Open loop G(s) = 1.6 × 20 × 2 ÷ (s(0.5s + 1)) = 64 ÷ (s(0.5s + 1)).
  • Closed loop: 64 ÷ (0.5s² + s + 64) = 128 ÷ (s² + 2s + 128).
  • ωₙ = √128 = 11.3 rad/s; ζ = 2 ÷ (2 × 11.3) = 0.088: very oscillatory. Velocity (tacho) feedback is added to increase damping (next topics).

Exams usually ask

  • Describe the principles and uses of potentiometers, synchros, encoders, tachogenerators and servomotors.
  • Draw the block diagram of a position or speed control system with its components.

Common mistake

Using a tachogenerator to measure position. It measures speed; position comes from integrating or from a position sensor.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All MEG 502 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.