2 min readBlock diagram elements
Blocks (transfer functions), arrows (signals), summing points (+ and − inputs) and take-off points.
Basic rules
| Arrangement | Equivalent |
|---|---|
| Blocks in series G₁, G₂ | G₁G₂ |
| Blocks in parallel (added) | G₁ + G₂ |
| Negative feedback loop | G ÷ (1 + GH) |
| Positive feedback loop | G ÷ (1 − GH) |
| Moving a take-off point ahead of a block G | add a block G in the branch |
| Moving a summing point ahead of a block G | add 1/G in the other input |
Worked example: block reduction
Forward path G₁ = 10/(s + 1) then G₂ = 1/s; inner feedback H₁ = 2 around G₂; outer unity feedback.
- Inner loop: G₂ ÷ (1 + G₂H₁) = (1/s) ÷ (1 + 2/s) = 1/(s + 2).
- Forward path: 10 ÷ ((s + 1)(s + 2)).
- Closed loop: 10 ÷ ((s + 1)(s + 2) + 10) = 10 ÷ (s² + 3s + 12).
- d.c. gain = 10/12 = 0.833.
Signal flow graphs
Nodes are signals; directed branches carry gains. Terms:
- Forward path: from input to output without visiting a node twice.
- Loop: closed path returning to its start.
- Non-touching loops: loops with no node in common.
Mason's gain formula
T = Σ Pₖ Δₖ ÷ Δ
where Pₖ is the gain of the k-th forward path, Δ = 1 − (sum of all loop gains) + (sum of products of every pair of non-touching loops) − (sum of products of triples) + ..., and Δₖ is Δ computed after removing the loops touching path k.
Worked example: Mason on the block diagram above
- One forward path: P₁ = G₁G₂ = 10/(s(s + 1)).
- Loops: L₁ = −G₂H₁ = −2/s; L₂ = −G₁G₂ = −10/(s(s + 1)). They share a node (both include G₂), so no non-touching pairs.
- Δ = 1 + 2/s + 10/(s(s + 1)); both loops touch the path, so Δ₁ = 1.
- T = [10/(s(s + 1))] ÷ [1 + 2/s + 10/(s(s + 1))]. Multiply top and bottom by s(s + 1): T = 10 ÷ (s(s + 1) + 2(s + 1) + 10) = 10 ÷ (s² + 3s + 12) ✓, the same as block reduction.
Disturbance inputs
With a disturbance D entering before the plant G₂ and a controller G₁ with unity feedback, C/D = G₂ ÷ (1 + G₁G₂). A large controller gain G₁ makes C/D small: feedback rejects the disturbance.
Exams usually ask
- Reduce a block diagram to a single transfer function.
- Draw a signal flow graph and apply Mason's formula.
Common mistake
Missing the minus sign for a negative feedback loop gain in Mason's formula, or counting touching loops as non-touching.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Block diagram
(opens en.wikipedia.org in a new tab)
Wikipedia, Block diagram, CC BY-SA 4.0 · licence
-
Signal-flow graph
(opens en.wikipedia.org in a new tab)
Wikipedia, Signal-flow graph, CC BY-SA 4.0 · licence
-
NPTEL: Control Engineering (IIT Madras and IIEST Shibpur, whole course)
12 weeks: modelling, block diagrams, time response, root locus design, frequency-domain design, state-space analysis and design. Video lectures, many hours in all: watch on Wi-Fi where you can.
(opens nptel.ac.in in a new tab)
NPTEL, NPTEL: Control Engineering (IIT Madras and IIEST Shibpur, whole course), CC BY-NC-SA 4.0 · licence
Watch
-
Best pick Problem 2 on Converting Block Diagram to Signal Flow Graph
13 min · ≈ 59 MB · about ₦33
(opens youtube.com in a new tab)
-
Introduction to Signal Flow Graphs
27 min · ≈ 122 MB · about ₦69
(opens youtube.com in a new tab)
-
Procedure to convert Signal Flow Graph to Block Diagram with example (Control system)
15 min · ≈ 68 MB · about ₦38
(opens youtube.com in a new tab)
-
LCS - 52b - Signal flow graphs for state-space models
8 min · ≈ 36 MB · about ₦20
(opens youtube.com in a new tab)
-
Draw Signal Flow Graph from system equations | Converting set of equations to Signal flow graph
10 min · ≈ 45 MB · about ₦25
(opens youtube.com in a new tab)
-
Block Diagram Algebra
1 h 29 min · ≈ 401 MB · about ₦225
(opens youtube.com in a new tab)
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.