UNIHIVE

Study Hub UNIPORT MEG 309

MEG 309 · Basic Metallurgy and Materials Selection

Preventing, measuring and monitoring corrosion

Design, coatings, cathodic protection, inhibitors, and coupons, probes and thickness surveys.

Our notes

2 min read

Approaches

Attack any part of the corrosion cell: the metal, the environment, the electrical path, or the surface.

Good design

  • Avoid crevices, pockets and water traps; allow drainage.
  • Avoid joining dissimilar metals, or insulate them.
  • Avoid small anodes with large cathodes.
  • Allow access for inspection and painting.
  • Add a corrosion allowance: extra thickness to be lost over the design life.

Material choice

Stainless steels, aluminium, copper alloys, plastics or composites where corrosion is severe.

Coatings

TypeExamplesHow it protects
PaintPrimer + topcoatsBarrier
Metallic, sacrificialGalvanising (zinc)Barrier, and zinc corrodes first
Metallic, nobleTin, chromium, nickelBarrier only: fails if scratched
ConversionPhosphating, anodising (aluminium)Thin protective layer
Pipeline coatingsFusion-bonded epoxy, polyethyleneBarrier

Surface preparation (removing rust and mill scale, often by blasting) decides how long a coating lasts.

Cathodic protection

Make the whole structure a cathode:

  • Sacrificial anodes: zinc, aluminium or magnesium blocks attached to the steel corrode instead: ship hulls, jetties, buried pipelines.
  • Impressed current: a DC power source with inert anodes drives current onto the structure: long pipelines and large structures.

Coatings and cathodic protection are used together: the coating does most of the work, CP protects the gaps.

Inhibitors

Chemicals added in small amounts to a liquid to slow corrosion: in boiler water, cooling systems, oil and gas pipelines and radiator coolant.

Environment control

  • Remove oxygen from boiler water.
  • Control pH.
  • Dehumidify air.

Measuring and monitoring

MethodHow
Weight-loss couponsWeigh, expose, clean, re-weigh (see the rate formula)
Electrical resistance (ER) probesResistance rises as the element thins
Linear polarisation resistance (LPR)Electrochemical rate in conducting liquids
Ultrasonic thickness (UT)Measures remaining wall thickness from outside
Pipeline pigs (intelligent)Travel inside pipelines and map metal loss
CP surveysMeasure pipe-to-soil potential
Visual inspectionSimple and vital

Worked example: remaining life

A pipe wall was 12.0 mm; a UT survey now reads 9.6 mm after 8 years. The minimum allowed thickness is 6.0 mm.
Rate = (12.0 − 9.6) ÷ 8 = 0.30 mm/year.
Remaining life = (9.6 − 6.0) ÷ 0.30 = 12 years.
Check: 9.6 − 12 × 0.30 = 9.6 − 3.6 = 6.0 mm. Correct. Plan inspection well before then, since rates can change.

Cost of corrosion

Studies in several countries estimate the cost of corrosion at a few percent of GDP, with much of it avoidable by known methods. Pipeline leaks in the Niger Delta add environmental and social costs.

Exams usually ask

  • Explain sacrificial and impressed-current cathodic protection.
  • Describe three methods of corrosion monitoring.

Common mistake

Relying on a noble coating such as tin over steel with scratches. At a scratch the steel is the anode and corrodes faster.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All MEG 309 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.