UNIHIVE

Study Hub UNIPORT CHM 349

CHM 349 · Chemical Kinetics

Interpreting kinetic data

Finding orders and rate constants from experiments: initial rates, isolation, half-lives and graphs.

Our notes

2 min read

The problem

An experiment gives concentration against time, or rate against concentration. You must find the order for each reactant and the rate constant.

Method 1: initial rates

Measure the rate at the very start (t → 0) for several starting mixtures, changing one concentration at a time. If doubling [A] doubles the rate, the order in A is 1; if it quadruples, 2; if no change, 0. In general, order = log(rate ratio)/log(concentration ratio).

Worked example: initial rates

Run[A]₀ (mol dm⁻³)[B]₀Initial rate (mol dm⁻³ s⁻¹)
10.100.102.0 × 10⁻⁴
20.200.108.0 × 10⁻⁴
30.100.204.0 × 10⁻⁴
  • Runs 1 and 2: [A] doubles, rate × 4, so order in A = 2.
  • Runs 1 and 3: [B] doubles, rate × 2, so order in B = 1.
  • Rate = k[A]²[B]; k = 2.0 × 10⁻⁴/(0.10² × 0.10) = 0.20 dm⁶ mol⁻² s⁻¹.

Method 2: isolation (flooding)

Make every reactant except A present in large excess (say 50 times). Their concentrations hardly change, so rate = k′[A]^m with a pseudo rate constant k′ = k[B]₀^n. Find m from one run, then repeat with a different [B]₀ to find n from how k′ changes.

Method 3: half-lives

Since t½ ∝ [A]₀^(1−n), compare half-lives at two starting concentrations. Example: t½ = 50 s when [A]₀ = 0.10 and 100 s when [A]₀ = 0.050. Halving [A]₀ doubled t½: 2 = (0.5)^(1−n), so 1 − n = −1 and n = 2.

Method 4: integrated-law graphs

Plot [A], ln[A] and 1/[A] against time. The one that gives a straight line shows the order; the slope gives k. Use enough of the reaction (at least two half-lives): over the first 10-20% all three plots look straight.

Method 5: fitting

Today the data are usually fitted by computer (least squares) to the integrated law, which also gives the uncertainty in k. Residuals that curve in one direction mean the wrong order was assumed.

Following the concentration

Any property proportional to concentration can be used: absorbance (Beer-Lambert), conductance, pressure (gas reactions), optical rotation, pH, or titrating samples taken out and quenched.

Exams usually ask

  • Find orders and k from an initial-rates table.
  • Explain the isolation method and pseudo-first-order constants.

Common mistake

Forgetting the units of k: they depend on overall order (s⁻¹ for first order, dm³ mol⁻¹ s⁻¹ for second, dm⁶ mol⁻² s⁻¹ for third).

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Practise

We link to free material and never copy it. Every link was opened by our team before it went up.

All CHM 349 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.