UNIHIVE

Study Hub UNIPORT CHM 349

CHM 349 · Chemical Kinetics

Experimental methods for following reactions

Conventional sampling and physical methods, temperature control, and flow methods for reactions finished in seconds.

Our notes

2 min read

The time scale decides the method

Half-lifeMethod
Minutes to daysconventional: mix, then follow by sampling or a physical property
About 1 ms to 10 sflow methods (continuous or stopped flow)
Below 1 msrelaxation and flash photolysis (next topics)

The mixing time must be short compared with the half-life, or the start of the reaction is lost.

Conventional methods

  • Chemical (sampling): take samples at intervals, quench them (cool quickly, dilute, or remove a catalyst or reagent) and analyse by titration or chromatography. Example: hydrolysis of an ester followed by titrating the acid formed.
  • Physical: follow a property continuously without disturbing the mixture: UV-visible absorbance, conductivity (ions formed or used), total pressure (gas reactions with a change in moles), volume (dilatometry, used for polymerisation), optical rotation (sucrose inversion), NMR or IR.

Temperature control

k changes strongly with T (often 2-4 times per 10 K), so the vessel sits in a thermostat held to ±0.1 K. A 1 K error in a reaction with Ea = 100 kJ mol⁻¹ changes k by about 14%.

Continuous flow

Two solutions are pumped into a mixing chamber and flow along a tube. Distance along the tube corresponds to time since mixing (time = distance ÷ flow speed). A detector moved along the tube reads the composition at each "age". It uses a lot of solution, which matters for expensive enzymes.

Stopped flow

Small volumes are driven by syringes through a mixer into an observation cell; the flow is then stopped suddenly and the detector records the change with time. Dead time about 1 ms. It is the standard method for enzyme and metal-complex reactions.

Quenched flow

The mixture flows for a set time and is then mixed with a quenching agent; the product is analysed afterwards. Useful when no fast-reading detector exists.

Gas-phase methods

  • Discharge flow: atoms or radicals made in a microwave discharge flow down a tube and react with an added gas; detected by resonance fluorescence or mass spectrometry. Used for atmospheric reactions (O + NO₂, OH + CH₄).
  • Shock tubes: a shock wave heats a gas to thousands of kelvin in microseconds, for combustion studies.

Exams usually ask

  • Choose a method for a given half-life and explain why.
  • Describe stopped flow with a labelled diagram.

Common mistake

Using sampling for a fast reaction without quenching: the reaction carries on while you titrate, so the concentrations are wrong.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

We link to free material and never copy it. Every link was opened by our team before it went up.

All CHM 349 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.