Why control

Chemical plants face disturbances all the time: feed composition changes, ambient temperature swings (cool harmattan mornings, hot afternoons), catalyst activity falls, steam pressure varies, and operators change production rates. Without control, temperatures, pressures, levels and compositions would drift, risking accidents, off-spec product and waste.

Objectives of control

  1. Safety: keep pressures, temperatures and concentrations within safe limits; protect people and equipment.
  2. Product quality: meet specifications (purity, octane number, moisture).
  3. Environmental protection: meet emission and effluent limits.
  4. Operational constraints: avoid flooding columns, pump cavitation, overfilling tanks.
  5. Economics: maximise throughput and yield, minimise energy and raw material use.

Variables

VariableMeaningStirred-tank heater example
Controlled variable (CV)What we want to keep at a set pointOutlet temperature T
Manipulated variable (MV)What we adjustSteam flow to the coil
Disturbance (load)What changes and upsets the processInlet temperature, feed flow
Set point (SP)Desired value of the CV80°C
Measured variableThe sensor's reading of the CVThermocouple signal

The feedback loop

Sensor measures the CV → transmitter sends a signal (4-20 mA) → controller compares it with the set point and computes an output from the error (e = SP − measurement) → final control element (usually a control valve) changes the MV → the process responds. The loop corrects any disturbance after it affects the CV.

Feedback versus feedforward

  • Feedback: acts on the measured CV; corrects any disturbance, even unknown ones, but only after an error appears.
  • Feedforward: measures the disturbance and acts before the CV changes; needs a model; cannot correct unmeasured disturbances. The two are often combined.

Worked example: steady-state heat balance

A tank heater warms 2 kg/s of water from 30°C to 80°C (c = 4.18 kJ/kg K). Heat needed = 2 × 4.18 × 50 = 418 kW. With steam giving 2,100 kJ/kg on condensing, the steam flow = 418 ÷ 2,100 = 0.199 kg/s. If the inlet falls to 25°C (a disturbance), the controller must raise steam to 2 × 4.18 × 55 ÷ 2,100 = 0.219 kg/s, a 10% increase. Check: the extra 5 K × 2 × 4.18 = 41.8 kW ÷ 2,100 = 0.0199 kg/s more steam. ✓

Exams usually ask: state the objectives of process control; define controlled, manipulated and disturbance variables; draw and explain a feedback loop for a given process; compare feedback and feedforward.

Common mistake: choosing a variable as manipulated that the plant cannot actually adjust (for example, "inlet temperature" when it comes from an upstream unit). The MV must be something a valve or drive can change.