CHE 513 · Process Dynamics and Control
Our notes
2 min readBlock diagrams
Each element is a block with its transfer function; signals flow along arrows; summing junctions add or subtract signals; take-off points split a signal. The standard feedback loop: set point → comparator → Gc (controller) → Gv (valve) → Gp (process) → output, with Gd (disturbance) adding to the output and Gm (measurement) in the feedback path.
Block algebra rules
| Arrangement | Equivalent |
|---|---|
| Blocks in series | Product G₁G₂ |
| Blocks in parallel | Sum G₁ + G₂ |
| Negative feedback loop (forward G, feedback H) | G ÷ (1 + GH) |
The closed-loop transfer functions
With Y = output, R = set point, D = disturbance, and the open-loop transfer function G_OL = Gc Gv Gp Gm:
- Servo problem (set-point change, D = 0): Y/R = Km Gc Gv Gp ÷ (1 + G_OL) (Km scales the set point into the same units as the measurement).
- Regulator problem (disturbance change, R = 0): Y/D = Gd ÷ (1 + G_OL).
Both share the denominator; 1 + G_OL = 0 is the characteristic equation, whose roots decide stability and speed.
Signal flow diagrams and Mason's rule
An alternative graph of nodes (variables) and branches (gains); Mason's gain formula gives the overall transfer function of complex networks directly.
Worked example: a first-order process under P control
Gp = 2 ÷ (5s + 1), Gc = Kc = 2, Gv = Gm = 1, Km = 1.
- Y/R = (2 × 2/(5s + 1)) ÷ (1 + 4/(5s + 1)) = 4 ÷ (5s + 1 + 4) = 4 ÷ (5s + 5) = 0.8 ÷ (1s + 1).
- The closed loop is still first-order, with gain 0.8 (the offset seen earlier) and time constant 1 instead of 5: feedback has made the response five times faster.
Check: τ_closed = τ ÷ (1 + KcK) = 5 ÷ 5 = 1; gain = 4/5 = 0.8. ✓
Worked example: PI control of the same process
Gc = Kc(1 + 1/(τI s)) with Kc = 1, τI = 5 (equal to the process time constant). G_OL = (1)(5s + 1)/(5s) × 2/(5s + 1) = 2 ÷ (5s). Y/R = (2/(5s)) ÷ (1 + 2/(5s)) = 2 ÷ (5s + 2) = 1 ÷ (2.5s + 1): gain 1 (no offset) and time constant 2.5. Check by the final value theorem for a unit step: lim s × 1/(2.5s + 1) × 1/s = 1. ✓
Exams usually ask: draw the block diagram of a feedback loop; reduce block diagrams; derive closed-loop transfer functions for servo and regulator problems; find closed-loop gains, time constants and offsets.
Common mistake: putting the disturbance transfer function in the denominator. Gd appears only in the numerator of Y/D; the denominator is always 1 + G_OL.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Best pick Woolf, Chemical Process Dynamics and Controls, 9.1 Constructing block diagrams
(opens eng.libretexts.org in a new tab)
LibreTexts, Woolf, Chemical Process Dynamics and Controls, 9.1 Constructing block diagrams, CC BY 3.0 · licence
-
Transfer function
(opens en.wikipedia.org in a new tab)
Wikipedia, Transfer function, CC BY-SA 4.0 · licence
-
Block diagram
(opens en.wikipedia.org in a new tab)
Wikipedia, Block diagram, CC BY-SA 4.0 · licence
-
Closed-loop transfer function
(opens en.wikipedia.org in a new tab)
Wikipedia, Closed-loop transfer function, CC BY-SA 4.0 · licence
Watch
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.