2 min readThe ideal Rankine cycle
The basic cycle of steam power plants:
1-2. Turbine: isentropic expansion of steam, producing work.
2-3. Condenser: constant-pressure heat rejection; steam to saturated liquid.
3-4. Pump: isentropic compression of liquid to boiler pressure.
4-1. Boiler: constant-pressure heat addition to superheated steam.
Per kg of steam:
- Turbine work w_t = h₁ − h₂
- Pump work w_p = h₄ − h₃ ≈ v₃(p₄ − p₃)
- Heat added q_in = h₁ − h₄
- Thermal efficiency η = (w_t − w_p)/q_in
- Back work ratio = w_p/w_t (very small for steam: an advantage over gas cycles).
- Specific steam consumption = 3,600/w_net (kg/kWh).
Why not Carnot?
A Carnot cycle using wet steam would need to compress a wet mixture (hard) and limits heat addition to the two-phase region (low temperature). Rankine is practical.
Worked example: ideal Rankine cycle
Boiler 4 MPa, 400 °C; condenser 10 kPa.
- State 1 (4 MPa, 400 °C): h₁ = 3,213.6 kJ/kg, s₁ = 6.7690 kJ/(kg·K).
- State 2 (10 kPa, s₂ = s₁): s_f = 0.6493, s_fg = 7.5009 → x₂ = (6.7690 − 0.6493)/7.5009 = 0.816; h₂ = 191.83 + 0.816 × 2,392.8 = 2,144.1 kJ/kg.
- State 3: h₃ = 191.83 kJ/kg, v₃ = 0.00101 m³/kg.
- Pump: w_p = 0.00101 × (4,000 − 10) = 4.03 kJ/kg; h₄ = 195.86 kJ/kg.
- w_t = 3,213.6 − 2,144.1 = 1,069.5 kJ/kg; q_in = 3,213.6 − 195.86 = 3,017.7 kJ/kg.
- η = (1,069.5 − 4.03)/3,017.7 = 35.3%. Back work ratio = 0.4%.
- Steam rate = 3,600/1,065.5 = 3.38 kg/kWh: a 100 MW plant needs about 338 t of steam per hour.
Ways to raise efficiency
Raise the average temperature of heat addition or lower the temperature of heat rejection:
- Lower condenser pressure (limited by cooling water temperature; increases wetness at turbine exit).
- Superheat to higher temperature (limited by materials, about 540-620 °C; reduces wetness).
- Raise boiler pressure (increases wetness unless reheated); supercritical plants above 22.1 MPa reach efficiencies above 40-45%.
Reheat cycle
Steam expands in a high-pressure turbine, returns to the boiler to be reheated, then expands in a low-pressure turbine. Main benefit: drier steam at exit (exit quality should be above about 0.88-0.90 to limit blade erosion), with a small gain in efficiency.
Regenerative cycle
Steam is bled from the turbine to heat feedwater (see the feedwater heaters topic). Raises the average temperature of heat addition: the biggest practical gain; nearly all large plants use several heaters.
Real cycles
Turbine and pump isentropic efficiencies (turbine about 85-90%), pressure drops, heat losses. Actual turbine work = η_t × (h₁ − h₂s).
Exams usually ask
- Sketch the Rankine cycle on T-s and h-s diagrams.
- Calculate work, heat, efficiency and steam rate using steam tables.
- Explain the effect of pressure, superheat, reheat and condenser pressure on efficiency.
Common mistake
Forgetting pump work or using h_g instead of h_f at the condenser exit. The pump takes saturated liquid (h_f).
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Best pick University Physics Volume 2, 4.2 Heat Engines
(opens openstax.org in a new tab)
OpenStax, University Physics Volume 2, 4.2 Heat Engines, CC BY-NC-SA 4.0 · licence
-
University Physics Volume 2, 4.5 The Carnot Cycle
(opens openstax.org in a new tab)
OpenStax, University Physics Volume 2, 4.5 The Carnot Cycle, CC BY-NC-SA 4.0 · licence
-
Rankine cycle
(opens en.wikipedia.org in a new tab)
Wikipedia, Rankine cycle, CC BY-SA 4.0 · licence
-
Thermal power station
(opens en.wikipedia.org in a new tab)
Wikipedia, Thermal power station, CC BY-SA 4.0 · licence
-
OpenStax, University Physics Volume 2 (whole free textbook)
The whole book, free to read online or download as a PDF (the PDF is large: Wi-Fi).
(opens openstax.org in a new tab)
OpenStax, OpenStax, University Physics Volume 2 (whole free textbook), CC BY-NC-SA 4.0 · licence
Watch
-
Mechanical Engineering Thermodynamics - Lec 21, pt 2 of 5: Example - Regen-Reheat Rankine - i
9 min · ≈ 41 MB · about ₦23
(opens youtube.com in a new tab)
-
Rankine Cycle - Steam Power Plant
17 min · ≈ 77 MB · about ₦43
(opens youtube.com in a new tab)
-
Rankine cycle (Basics, Block Diagram, pV Diagram, Ts Diagram, Work done & Efficiency) Explained
9 min · ≈ 41 MB · about ₦23
(opens youtube.com in a new tab)
-
Rankine Cycle Efficiency and Net Power Output Calculations
23 min · ≈ 104 MB · about ₦58
(opens youtube.com in a new tab)
-
Lecture 02 Steam Power Plant Cycle
35 min · ≈ 158 MB · about ₦89
(opens youtube.com in a new tab)
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.