PSM 405 · Environmental Health
Our notes
2 min readLarge-scale treatment
- Storage: settling of suspended matter, some die-off of pathogens.
- Screening: removes floating debris.
- Coagulation and flocculation: alum (aluminium sulphate) makes fine particles clump into flocs.
- Sedimentation: flocs settle.
- Filtration:
- Slow sand filters: a biological layer (schmutzdecke) on the sand removes most bacteria; simple but need large areas.
- Rapid sand filters: faster, cleaned by backwashing; rely on coagulation and disinfection.
- Disinfection: usually chlorination; others are ozone and UV.
Chlorination: dose = chlorine demand + residual. The WHO advises a free chlorine residual of at least 0.5 mg/L after at least 30 minutes' contact (at pH below 8), and a residual of about 0.2 to 0.5 mg/L at the point of delivery.
Chlorination calculation
Worked example 1. Disinfect a 10,000-litre tank at 2 mg/L using high-test hypochlorite (HTH, 70% available chlorine).
- Chlorine needed = 10,000 L × 2 mg/L = 20,000 mg = 20 g of available chlorine.
- HTH needed = 20 ÷ 0.70 = 28.6 g.
Worked example 2 (shock-chlorinating a well). A well 1.5 m in diameter with 4 m of water: volume = π × 0.75² × 4 = 3.1416 × 0.5625 × 4 = 7.069 m³ = 7,069 L. At a shock dose of 50 mg/L (follow the local guideline): 7,069 × 50 = 353,450 mg = 353 g of chlorine, so HTH = 353 ÷ 0.70 = 505 g. Leave for the recommended contact time, then pump out until the chlorine smell is faint.
Household water treatment
- Boiling: bring to a rolling boil (about 1 minute); kills pathogens but uses fuel and does not remove chemicals.
- Chlorination: tablets or dilute hypochlorite, following the product's dose; wait 30 minutes.
- Solar disinfection (SODIS): clear PET bottles (up to 2 L) in full sun for at least 6 hours (two days if cloudy).
- Filtration: ceramic or bio-sand filters.
- Safe storage: narrow-necked covered containers with a tap; never dip cups into stored water.
Water safety plans
The WHO approach: assess risks from catchment to tap and control them at each step, rather than relying only on end-product testing.
Exams usually ask: describe the stages of water treatment; compare slow and rapid sand filters; explain chlorine demand and residual; calculate chlorine doses; list household treatment methods.
Common mistake: adding only enough chlorine to meet the demand. A free residual must remain to show disinfection is complete and to protect against later contamination.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Best pick Introduction to Water Systems Technology, 1.7 Water treatment facilities and operations
(opens workforce.libretexts.org in a new tab)
-
Water purification
(opens en.wikipedia.org in a new tab)
Wikipedia, Water purification, CC BY-SA 4.0 · licence
-
Water chlorination
(opens en.wikipedia.org in a new tab)
Wikipedia, Water chlorination, CC BY-SA 4.0 · licence
-
Slow sand filter
(opens en.wikipedia.org in a new tab)
Wikipedia, Slow sand filter, CC BY-SA 4.0 · licence
-
Solar water disinfection
(opens en.wikipedia.org in a new tab)
Wikipedia, Solar water disinfection, CC BY-SA 4.0 · licence
-
NOUN EHS 419: Sanitary Engineering
NOUN course book (PDF, about 0.8 MB). Water treatment, storage and distribution; sewage treatment.
(opens nou.edu.ng in a new tab)
-
NOUN EHS 318: Introduction to Water Resources Management
NOUN course book (PDF, about 1 MB). Water sources, quality and treatment.
(opens nou.edu.ng in a new tab)
We link to free material and never copy it. Every link was opened by our team before it went up.