UNIHIVE

Study Hub UNIPORT PHY 411

PHY 411 · Applied Geophysics (for non-Geophysics majors)

Induced polarisation and self-potential

Polarisation effects, time- and frequency-domain IP, chargeability and metal factor, and natural self-potentials.

Our notes

2 min read

Induced polarisation (IP): the effect

When current flowing through the ground is switched off, the measured voltage does not drop to zero at once but decays over a second or so; when switched on, it builds up gradually. The ground acts a little like a capacitor because charge piles up at:

  • Electrode (metallic) polarisation: interfaces between pore water and electronically conducting grains (sulphides, graphite, magnetite).
  • Membrane polarisation: clay particles and narrow pores that block ions.

Disseminated sulphides (small grains scattered through rock) are poor at conducting current as a whole, so resistivity may miss them, but they give strong IP: the main reason IP was developed.

Measurements

Time domain

Square-wave current on and off. After switch-off, integrate the decaying voltage over a time window and divide by the primary voltage: the chargeability M, in milliseconds (or mV/V).

Frequency domain

Measure apparent resistivity at two frequencies (e.g. 0.1 and 1 Hz). Polarisable ground has lower resistivity at the higher frequency.

  • Frequency effect: FE = (ρ_dc − ρ_ac)/ρ_ac.
  • Metal factor: MF = 2π × 10⁵ × (ρ_dc − ρ_ac)/(ρ_dc ρ_ac): high where polarisable and conductive (metallic).

Spectral IP

Measures phase and amplitude over many frequencies to tell sulphides from clays.

Field practice

Dipole-dipole and gradient arrays; non-polarisable potential electrodes (copper-copper sulphate porous pots); powerful transmitters; careful separation of current and potential wires to avoid electromagnetic coupling. Results are shown as pseudosections of apparent chargeability and resistivity, then inverted.

Uses of IP

Porphyry copper and disseminated sulphide deposits (worldwide, the main use), gold associated with sulphides, clay and groundwater studies, contamination and landfill mapping.

Self-potential (SP)

Natural voltages in the ground, measured between two non-polarisable electrodes with a high-impedance voltmeter, with no current injected.
Sources:

  • Mineralisation potential: a sulphide or graphite body spanning the water table acts like a battery (oxidation near the surface, reduction below), giving strong negative anomalies (hundreds of millivolts) over the top of the body.
  • Streaming (electrokinetic) potential: water flowing through porous rock, e.g. seepage through dams and embankments, geothermal flow.
  • Diffusion (liquid-junction) and membrane potentials: differences in ion concentration (the basis of the SP well log at sand-shale boundaries).
  • Background: small, slowly varying potentials and noise from telluric currents and pipelines.

Field methods: fixed-base (one electrode fixed, the other moved) or gradient (both move at fixed spacing).

Uses of SP

Quick, cheap reconnaissance for sulphides and graphite, seepage under dams and levees, geothermal areas, and in wells (shale and sand boundaries, water resistivity).

Exams usually ask

  • Explain the causes of IP and define chargeability, frequency effect and metal factor.
  • Why IP finds disseminated sulphides that resistivity misses.
  • Sources and uses of self-potential anomalies.

Common mistake

Using metal stakes as potential electrodes in IP or SP surveys. They polarise and give false voltages; use non-polarisable porous-pot electrodes.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All PHY 411 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.