Magnetisation

Atoms carry tiny magnetic dipoles (electron orbits and spins). In a field they may line up. Magnetisation M = magnetic dipole moment per unit volume (A/m).

Bound currents

A magnetised material acts like:

  • Volume bound current J_b = ∇×M.
  • Surface bound current K_b = M × n̂.

A uniformly magnetised rod is like a solenoid with surface current M.

The H field

Total current = free + bound: ∇×B = μ₀(J_f + ∇×M). Define H = B/μ₀ − M. Then:
∇×H = J_f, or ∮ H·dl = I_f,enc: only free current appears (like D in dielectrics). H is set by the currents you control; its unit is A/m.

Linear materials

M = χₘH (χₘ = magnetic susceptibility). Then B = μ₀(1 + χₘ)H = μH, with μᵣ = 1 + χₘ.

Kinds of magnetic material

  • Diamagnetic: χₘ small and negative (about −10⁻⁵): the induced moments oppose the field (copper, water, bismuth). Weakly repelled. All materials have this effect; superconductors are perfect diamagnets (χₘ = −1, the Meissner effect).
  • Paramagnetic: χₘ small and positive (10⁻⁵ to 10⁻³): permanent atomic moments partly line up (aluminium, oxygen). Curie's law: χ = C/T (weaker when hotter).
  • Ferromagnetic: very large, field-dependent μᵣ (hundreds to over 100,000): iron, nickel, cobalt and their alloys. Strong exchange forces align neighbouring moments in domains. Above the Curie temperature (iron about 770 °C) they become paramagnetic.
  • Antiferromagnetic and ferrimagnetic (ferrites): neighbouring moments opposed, fully or partly.

Hysteresis

In a ferromagnet, B depends on its history.

  • Increase H from zero: B rises along the magnetisation curve to saturation.
  • Reduce H to zero: B stays at the remanence Bᵣ.
  • Reverse H to the coercive field H_c to bring B back to zero.
  • The area of the hysteresis loop = energy lost per unit volume per cycle (heat).

Soft materials (silicon steel, soft iron): narrow loops, low losses: transformer and motor cores. Hard materials (alnico, ferrites, NdFeB): wide loops, high H_c: permanent magnets.

Boundary conditions

With no free surface current: B⊥ continuous and H∥ continuous. Field lines leaving iron into air are nearly perpendicular to the surface.

Magnetic circuits

In a core with a small air gap: NI = H_iron l_iron + H_gap l_gap. Because μᵣ of iron is large, most of the "magnetomotive force" drops across the gap.
Example: N = 500, I = 1.0 A, gap 1.0 mm, iron path 0.30 m with μᵣ = 2,000. B = μ₀NI/(l_iron/μᵣ + l_gap) = 4π × 10⁻⁷ × 500/(1.5 × 10⁻⁴ + 1.0 × 10⁻³) = 6.283 × 10⁻⁴/1.15 × 10⁻³ = 0.546 T.
Check: without the iron term, B = 0.628 T; the iron adds 15% to the effective length, so 0.628/1.15 = 0.546. ✓

Exams usually ask

  • Define M, H, χₘ and μᵣ and derive J_b and K_b.
  • Distinguish dia-, para- and ferromagnetism.
  • Explain hysteresis and soft and hard magnetic materials.

Common mistake

Writing B = μ₀H inside iron. Inside a magnetic material B = μ₀(H + M), much larger in a ferromagnet.