UNIHIVE

Study Hub UNIPORT PHY 115

PHY 115 · Heat, Light and Sound

Optical instruments

The eye and its defects, the magnifying glass, compound microscope, telescope, camera and projector.

Our notes

2 min read

The human eye

  • The cornea and lens focus light on the retina; the iris controls the pupil size; the optic nerve takes the signal to the brain.
  • Accommodation: ciliary muscles change the lens shape so near and far objects focus. Normal near point D = 25 cm; far point at infinity.

Defects and how they are corrected

DefectProblemCorrection
Short sight (myopia)far objects blurred; image forms in front of retinadiverging lens
Long sight (hypermetropia)near objects blurred; image behind retinaconverging lens
Presbyopialens stiffens with agebifocals or reading glasses
Astigmatismcornea curved unevenlycylindrical lens

Worked example. A short-sighted student's far point is 2.0 m. She needs a lens that makes distant objects appear at 2.0 m: v = −2.0 m with u = ∞, so 1/f = 1/∞ + 1/(−2.0), f = −2.0 m, power −0.5 D (diverging).

Magnifying glass (simple microscope)

A converging lens with the object inside F gives a virtual, upright, enlarged image. With the image at the near point:
M = 1 + D/f. With f = 5 cm: M = 1 + 25/5 = 6. (With the image at infinity, M = D/f = 5.)

Compound microscope

Two converging lenses of short focal length: the objective makes a real, enlarged image inside the focal length of the eyepiece, which magnifies it again. Total magnification = m_objective × M_eyepiece. Example: objective ×10, eyepiece ×10: ×100. The final image is inverted.

Astronomical (refracting) telescope

Objective of long focal length f_o, eyepiece of short f_e. In normal adjustment the final image is at infinity:

  • Magnifying power M = f_o/f_e.
  • Length of tube = f_o + f_e.

Worked example. f_o = 100 cm, f_e = 5 cm: M = 20; tube length 105 cm. The image is inverted (fine for stars; a terrestrial telescope adds an erecting lens, and prism binoculars use TIR prisms to turn it the right way up and shorten the tube).

Camera and projector

  • Camera: converging lens forms a real, inverted, smaller image on the film or sensor; focus by moving the lens; the aperture and shutter speed control light. Compare with the eye: lens moves (camera) versus lens changes shape (eye); sensor versus retina; diaphragm versus iris.
  • Projector: slide just outside F of the projection lens, so the image is real, inverted and greatly enlarged on a distant screen; slides go in upside down. A concave mirror and condenser lens make the lighting bright and even.

Exams usually ask: label the eye and compare it with a camera; correct myopia and hypermetropia with a lens calculation; magnifying power of a magnifier and telescope; ray diagram of a microscope or telescope.

Common mistake: correcting short sight with a converging lens. Short-sighted eyes already bend light too much, so they need a diverging lens.