PHY 108 · General Physics Practical II

Measurement and instruments

Reading the metre rule, vernier calipers and micrometer screw gauge correctly, including zero error.

Our notes

2 min read

Choosing the right instrument

Every instrument has a least count (precision): the smallest division it can read. Pick an instrument whose least count suits the size of what you measure.

Length

InstrumentLeast countGood for
Metre rule0.1 cm (1 mm)lengths of tens of cm
Vernier calipers0.01 cm (0.1 mm)diameters of rods, beakers, internal and external
Micrometer screw gauge0.001 cm (0.01 mm)diameters of thin wires, thickness of paper
Measuring tape0.1 cmlong distances

Reading a vernier caliper

  1. Close the jaws and check the zero error (do the zeros line up?).
  2. Place the object between the jaws.
  3. Read the main scale just before the vernier zero (e.g. 2.3 cm).
  4. Find the vernier mark that lines up exactly with a main scale mark (e.g. the 4th): add 4 × 0.01 cm = 0.04 cm.
  5. Reading = 2.3 + 0.04 = 2.34 cm; then correct for zero error.

Reading a micrometer screw gauge

  1. Turn the ratchet (not the thimble directly) until the spindle just touches the object, so you do not squeeze it.
  2. Read the sleeve (main) scale: e.g. 5.5 mm.
  3. Read the thimble scale mark on the reference line: e.g. 28 × 0.01 mm = 0.28 mm.
  4. Reading = 5.5 + 0.28 = 5.78 mm; correct for zero error.

Zero error

  • If the instrument reads more than zero when closed (positive zero error), subtract it from readings.
  • If it reads less than zero (negative zero error), add it.

Corrected reading = observed reading − zero error (taking the sign of the error).

Other instruments

  • Mass: beam balance, electronic (top-pan) balance. Weight: spring balance (newtons).
  • Time: stopwatch or stop-clock (human reaction time is about 0.2 s, so time many oscillations, e.g. 20, and divide).
  • Temperature: liquid-in-glass thermometer (mercury or alcohol), thermocouple.
  • Volume: measuring cylinder (read at the bottom of the meniscus for water, at eye level), burette, pipette.
  • Electrical: ammeter (current, in series), voltmeter (potential difference, in parallel), galvanometer, multimeter, rheostat (variable resistor).
  • Angles: protractor, spectrometer.

Good reading practice

  • Read with your eye directly in line with the mark, to avoid parallax error.
  • Take each reading at least twice (or measure in several places and directions, for a wire diameter) and average.
  • Record readings to the precision of the instrument (a metre rule reading is 45.0 cm, not 45 cm).

Exams usually ask: least counts of instruments; read a vernier or micrometer from a diagram; zero error correction; how to connect ammeters and voltmeters; ways to reduce reading errors.

Common mistake: adding a positive zero error instead of subtracting it.