PHY 102.2 · Laboratory Practices II
Our notes
2 min readChoosing the right instrument
Every instrument has a least count (precision): the smallest division it can read. Pick an instrument whose least count suits the size of what you measure.
Length
| Instrument | Least count | Good for |
|---|---|---|
| Metre rule | 0.1 cm (1 mm) | lengths of tens of cm |
| Vernier calipers | 0.01 cm (0.1 mm) | diameters of rods, beakers, internal and external |
| Micrometer screw gauge | 0.001 cm (0.01 mm) | diameters of thin wires, thickness of paper |
| Measuring tape | 0.1 cm | long distances |
Reading a vernier caliper
- Close the jaws and check the zero error (do the zeros line up?).
- Place the object between the jaws.
- Read the main scale just before the vernier zero (e.g. 2.3 cm).
- Find the vernier mark that lines up exactly with a main scale mark (e.g. the 4th): add 4 × 0.01 cm = 0.04 cm.
- Reading = 2.3 + 0.04 = 2.34 cm; then correct for zero error.
Reading a micrometer screw gauge
- Turn the ratchet (not the thimble directly) until the spindle just touches the object, so you do not squeeze it.
- Read the sleeve (main) scale: e.g. 5.5 mm.
- Read the thimble scale mark on the reference line: e.g. 28 × 0.01 mm = 0.28 mm.
- Reading = 5.5 + 0.28 = 5.78 mm; correct for zero error.
Zero error
- If the instrument reads more than zero when closed (positive zero error), subtract it from readings.
- If it reads less than zero (negative zero error), add it.
Corrected reading = observed reading − zero error (taking the sign of the error).
Other instruments
- Mass: beam balance, electronic (top-pan) balance. Weight: spring balance (newtons).
- Time: stopwatch or stop-clock (human reaction time is about 0.2 s, so time many oscillations, e.g. 20, and divide).
- Temperature: liquid-in-glass thermometer (mercury or alcohol), thermocouple.
- Volume: measuring cylinder (read at the bottom of the meniscus for water, at eye level), burette, pipette.
- Electrical: ammeter (current, in series), voltmeter (potential difference, in parallel), galvanometer, multimeter, rheostat (variable resistor).
- Angles: protractor, spectrometer.
Good reading practice
- Read with your eye directly in line with the mark, to avoid parallax error.
- Take each reading at least twice (or measure in several places and directions, for a wire diameter) and average.
- Record readings to the precision of the instrument (a metre rule reading is 45.0 cm, not 45 cm).
Exams usually ask: least counts of instruments; read a vernier or micrometer from a diagram; zero error correction; how to connect ammeters and voltmeters; ways to reduce reading errors.
Common mistake: adding a positive zero error instead of subtracting it.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Vernier scale
(opens en.wikipedia.org in a new tab)
Wikipedia, Vernier scale, CC BY-SA 4.0 · licence
-
Micrometer (device)
(opens en.wikipedia.org in a new tab)
Wikipedia, Micrometer (device), CC BY-SA 4.0 · licence
-
College Physics 2e, 1.3 Accuracy, Precision, and Significant Figures
(opens openstax.org in a new tab)
OpenStax, College Physics 2e, 1.3 Accuracy, Precision, and Significant Figures, CC BY-NC-SA 4.0 · licence
Watch
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.