Radioactivity

Unstable nuclei decay, giving out radiation:

TypeWhat it isPenetrationStopped by
Alpha (α)helium nucleus, ⁴₂Helowpaper, skin
Beta (β⁻)electron from the nucleusmediuma few mm of aluminium or plastic
Positron (β⁺)positive electron; meets an electron and gives two 511 keV gamma rays
Gamma (γ)high-energy photonhighthick lead or concrete (reduced, not stopped)

Also electron capture and isomeric transition (metastable nuclei such as technetium-99m giving gamma only).

Decay law

Decay is first order: A = A₀ e^(−λt), with half-life t½ = 0.693 ÷ λ. Activity is measured in becquerels (Bq, one decay per second); the older unit, the curie (Ci), is 3.7 × 10¹⁰ Bq.

Worked example

Technetium-99m has t½ = 6.0 hours. A vial holds 800 MBq at 8 a.m.

  • At 2 p.m. (one half-life): 400 MBq.
  • At 8 p.m. (two half-lives): 200 MBq.
  • After 3 hours: 800 × (½) to the power 0.5 = 800 × 0.707 = 566 MBq.

Iodine-131 (t½ about 8.0 days): after 24 days (three half-lives) 1/8 remains.

Detection and measurement

Geiger-Müller counters (contamination monitoring), scintillation detectors (sodium iodide crystals in gamma cameras), ionisation chambers (dose calibrators that check the activity of each preparation before it leaves the radiopharmacy), and film or electronic badges (dosimeters) worn by staff.

Diagnostic radionuclides

An ideal imaging radionuclide emits gamma rays of suitable energy (100-200 keV), has a short half-life (hours), no alpha or beta particles, and is easily attached to carrier molecules.

  • Technetium-99m (140 keV gamma, 6 h) from a molybdenum-99 / technetium-99m generator; used for bone, kidney, heart, thyroid scans by attaching it to different kits.
  • Iodine-123 (thyroid), thallium-201 (heart), gallium-67, indium-111.
  • Fluorine-18 (positron, 110 min) as fluorodeoxyglucose in PET scanning.

Therapeutic radionuclides (iodine-131, beta emitters) exist too; their use is specialist and not covered here.

Safe handling and disposal

Principles: time (minimise), distance (inverse square law: doubling distance cuts dose rate to a quarter), shielding (lead pots, syringe shields), and ALARA (as low as reasonably achievable). Work in designated areas, wear gloves and dosimeters, monitor for contamination, keep records.

Waste with short half-lives is stored until it has decayed (about 10 half-lives leaves less than 0.1%) and then disposed of as ordinary waste if monitoring allows; long-lived waste goes to authorised disposal. In Nigeria the Nigerian Nuclear Regulatory Authority (NNRA) licenses the use of radioactive materials.

Worked example: inverse square law

A source gives 40 μSv/h at 0.5 m. At 2.0 m (four times as far): 40 ÷ 16 = 2.5 μSv/h.

Exams usually ask

  • Describe the types of radiation and calculate remaining activity after a given time.
  • State the properties of an ideal diagnostic radionuclide and the rules for safe handling and disposal.

Common mistake

Thinking 10 half-lives leaves nothing. It leaves 1/1,024 (about 0.1%) of the starting activity.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

Practise

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All PCH 221 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.