UNIHIVE

Study Hub UNIPORT PCH 221

PCH 221 · Pharmaceutical Chemistry I (Physical and Inorganic Pharmaceutical Chemistry)

Limit tests and assays of inorganic pharmaceuticals

The principle of limit tests for chloride, sulfate, iron, heavy metals and arsenic, and common assay methods.

Our notes

2 min read

Purpose of limit tests

Impurities come from raw materials, the manufacturing process, the container or decomposition. A limit test does not measure the exact amount of an impurity; it shows whether the amount is below a set limit by comparing the sample with a standard treated the same way.

Common limit tests (principles)

ImpurityReagentWhat you seeCompared with
Chloridesilver nitrate in dilute nitric acidwhite opalescence of AgClstandard NaCl solution
Sulfatebarium chloride (with a little potassium sulfate to seed) in HClwhite turbidity of BaSO₄standard K₂SO₄ solution
Ironthioglycollic acid in citric acid, made alkaline with ammoniapink-purple colour of ferrous thioglycollatestandard iron solution
Heavy metalssulfide (thioacetamide) at pH about 3.5brown-black metal sulfidesstandard lead solution
Arseniczinc and acid make arsine gas (AsH₃), which stains mercuric bromide paper (Gutzeit test)yellow-brown stainstandard arsenic stain

Why nitric acid in the chloride test? It stops other ions (carbonate, phosphate) from precipitating with silver. Why citric acid in the iron test? It keeps iron in solution, stopping it precipitating as hydroxide when ammonia is added.

Both test and standard are viewed side by side against a dark (or white) background in matched Nessler cylinders. If the sample's turbidity or colour is not deeper than the standard's, it passes.

Assays: common methods

  • Acid-base titration: sodium bicarbonate with standard HCl.
  • Complexometric (EDTA) titration: calcium, magnesium, zinc, aluminium salts (next topic).
  • Precipitation titration: chloride by silver nitrate (Mohr method, chromate indicator; Volhard back titration with thiocyanate).
  • Redox titration: ferrous sulfate with ceric ammonium sulfate or potassium permanganate; hydrogen peroxide with permanganate; iodine with sodium thiosulfate.
  • Gravimetry: weighing a precipitate (sulfate as BaSO₄).

Worked example: assay by titration

0.2500 g of sodium bicarbonate (NaHCO₃, 84.01 g/mol) needs 29.40 mL of 0.1000 M HCl.

  • Moles HCl = 0.02940 × 0.1000 = 0.002940 mol = moles NaHCO₃.
  • Mass = 0.002940 × 84.01 = 0.2470 g.
  • Content = 0.2470 ÷ 0.2500 × 100 = 98.8%.

Worked example: redox assay

Ferrous sulfate: 0.5000 g needs 17.60 mL of 0.1000 M ceric ammonium sulfate (Fe²⁺ + Ce⁴⁺ → Fe³⁺ + Ce³⁺, 1 : 1). FeSO₄·7H₂O = 278.0 g/mol.

  • Moles = 0.001760; mass = 0.001760 × 278.0 = 0.4893 g; content = 97.9%.

Exams usually ask

  • Explain the principle of the limit tests for chloride, sulfate, iron, heavy metals and arsenic, and the reason for each reagent.
  • Calculate the percentage content from titration data.

Common mistake

Thinking a limit test gives the amount of impurity. It only says above or below the limit.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

Practise

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All PCH 221 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.