UNIHIVE

Study Hub UNIPORT MEG 505

MEG 505 · Mechanical Vibration and Noise

Rotating unbalance, base excitation and vibration isolation

Response to unbalance, motion of a supported body under base motion, force and motion transmissibility, and designing isolators.

Our notes

2 min read

Rotating unbalance

An unbalanced mass m₀ at eccentricity e in a machine of total mass M turning at ω gives a force m₀ e ω² sin ωt. Steady state:
M X / (m₀ e) = r² / √[(1 − r²)² + (2ζr)²].
At low speed X is small; at resonance it peaks; at high speed X → m₀e/M (the machine spins about the combined centre of mass).

Base (support) excitation

The base moves y = Y sin ωt (a vehicle on a rough road, a machine on a vibrating floor, an instrument on a ship). The relative equation: m z̈ + c ż + k z = m ω² Y sin ωt (z = x − y). The absolute motion ratio:
X/Y = √[1 + (2ζr)²] / √[(1 − r²)² + (2ζr)²].

Transmissibility (TR)

The same expression gives

  • force transmissibility: force transmitted to the foundation ÷ applied force (machine on mounts);
  • motion transmissibility: X/Y (equipment protected from a moving base).

TR < 1 (isolation) only when r > √2. Below √2, mounts amplify.
In the isolation region, less damping gives better isolation, but damping is still needed to limit motion while passing through resonance at start-up and shut-down.

Worked example: design an isolator

A 200 kg machine runs at 1,500 rpm (ω = 157.1 rad/s). Required: 90% isolation (TR = 0.1), damping small.
Undamped: TR = 1/(r² − 1) = 0.1 ⇒ r² = 11, r = 3.32.
ω_n = 157.1/3.32 = 47.4 rad/s (7.5 Hz).
Total mount stiffness k = M ω_n² = 200 × 2,243 = 448.6 kN/m (about 112 kN/m for each of four mounts).
Static deflection δ = g/ω_n² = 9.81/2,243 = 4.37 mm.
(Checked by computer.)
If the machine has an unbalance m₀e = 0.05 kg m, its steady amplitude on these mounts is (m₀e/M) r²/(r² − 1) = (0.05/200)(11/10) = 0.275 mm.

Isolator types

Steel springs (low frequencies, little damping; add dampers), rubber and elastomer mounts (some damping, compact), air springs (very low frequencies), cork and felt pads (high frequencies), inertia blocks (add mass to lower the motion of the machine on its mounts).

Practical points

  • Choose mounts by static deflection and load; place them symmetrically about the centre of gravity to avoid coupled rocking.
  • Flexible connections for pipes, ducts and cables: a rigid pipe bypasses the mounts.
  • Check rocking and horizontal modes, not just vertical.
  • Isolating sensitive equipment (laboratory balances, microscopes) uses the same rules from the receiving end.

Exams usually ask

  • Derive transmissibility; show isolation needs r > √2.
  • Design spring mounts for a given machine and isolation level.
  • Response of machines with rotating unbalance; vehicles on wavy roads.

Common mistake

Adding damping to "improve isolation" in the operating range. Above r = √2, more damping increases transmitted force; damping helps only near resonance.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All MEG 505 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.