MEG 502 · Control Engineering
Our notes
2 min readSteady-state error
For a unity feedback system with open-loop G(s), the error E(s) = R(s) ÷ (1 + G(s)). By the final value theorem:
e_ss = lim (s → 0) s R(s) ÷ (1 + G(s))
(the closed loop must be stable).
System type
Write G(s) = K(1 + T_a s)... ÷ (sᴺ(1 + T₁s)...). Type N is the number of pure integrators (poles at s = 0) in G(s).
Error constants
| Input | Constant | Error |
|---|---|---|
| Unit step | K_p = lim G(s) as s → 0 | 1 ÷ (1 + K_p) |
| Unit ramp | K_v = lim s G(s) | 1 ÷ K_v |
| Unit parabola (t²/2) | K_a = lim s² G(s) | 1 ÷ K_a |
| Type | Step error | Ramp error | Parabola error |
|---|---|---|---|
| 0 | 1/(1 + K_p) | ∞ | ∞ |
| 1 | 0 | 1/K_v | ∞ |
| 2 | 0 | 0 | 1/K_a |
Each integrator removes the error for one more class of input. Integral action in a controller raises the type by one.
Worked example
G(s) = 20 ÷ (s(s + 4)) (type 1), unity feedback.
- Step: e_ss = 0.
- Ramp: K_v = lim s × 20/(s(s + 4)) = 20/4 = 5, so e_ss = 0.2 (for a unit ramp).
- Parabola: K_a = 0, error infinite.
For a ramp input of 3 rad/s (a radar dish tracking a target), the lag is 3 × 0.2 = 0.6 rad behind.
Worked example: type 0
G(s) = 50 ÷ ((s + 2)(s + 5)): K_p = 50/10 = 5; step error = 1/6 = 0.167 (16.7%). Raising the gain to reduce this error lowers the damping, so a PI controller is often better.
Disturbance error
For a constant disturbance entering before the plant, a type 1 controller (integral action) is needed to remove its steady-state effect; an integrator in the plant after the disturbance does not do it.
Non-unity feedback
Convert to an equivalent unity feedback system first: G_e = G ÷ (1 + GH − G), or work directly with E = R − C.
Exams usually ask
- Determine the system type and error constants, and the steady-state error for step, ramp and parabolic inputs.
- Find the gain needed to meet a steady-state error specification, and check stability.
Common mistake
Using the closed-loop transfer function in the error-constant formulas. They use the open-loop G(s).
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Final value theorem
(opens en.wikipedia.org in a new tab)
Wikipedia, Final value theorem, CC BY-SA 4.0 · licence
-
NPTEL: Control Engineering (IIT Delhi, Prof. M. Gopal, whole course)
41 lectures: the control problem, dynamic response, models of industrial control devices, Routh stability, root locus, Nyquist and stability margins, frequency-response design. Video lectures, many hours in all: watch on Wi-Fi where you can.
(opens nptel.ac.in in a new tab)
NPTEL, NPTEL: Control Engineering (IIT Delhi, Prof. M. Gopal, whole course), CC BY-NC-SA 4.0 · licence
Watch
-
Best pick Steady State Error
7 min · ≈ 32 MB · about ₦18
(opens youtube.com in a new tab)
-
Steady State Error Explained: Basics, Definition, Derivation, Calculation, and Formula
11 min · ≈ 50 MB · about ₦28
(opens youtube.com in a new tab)
-
Steady State Error Explained: Type 0, 1, & 2 Systems (Control Systems)
19 min · ≈ 86 MB · about ₦48
(opens youtube.com in a new tab)
-
Systems Analysis - Steady State Error
28 min · ≈ 126 MB · about ₦71
(opens youtube.com in a new tab)
-
System Dynamics and Control: Module 16 - Steady-State Error
42 min · ≈ 189 MB · about ₦106
(opens youtube.com in a new tab)
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.