UNIHIVE

Study Hub UNIPORT MEG 502

MEG 502 · Control Engineering

Steady-state error, system type and error constants

Final errors to step, ramp and parabolic inputs, the type number, and the position, velocity and acceleration constants.

Our notes

2 min read

Steady-state error

For a unity feedback system with open-loop G(s), the error E(s) = R(s) ÷ (1 + G(s)). By the final value theorem:

e_ss = lim (s → 0) s R(s) ÷ (1 + G(s))

(the closed loop must be stable).

System type

Write G(s) = K(1 + T_a s)... ÷ (sᴺ(1 + T₁s)...). Type N is the number of pure integrators (poles at s = 0) in G(s).

Error constants

InputConstantError
Unit stepK_p = lim G(s) as s → 01 ÷ (1 + K_p)
Unit rampK_v = lim s G(s)1 ÷ K_v
Unit parabola (t²/2)K_a = lim s² G(s)1 ÷ K_a
TypeStep errorRamp errorParabola error
01/(1 + K_p)∞∞
101/K_v∞
2001/K_a

Each integrator removes the error for one more class of input. Integral action in a controller raises the type by one.

Worked example

G(s) = 20 ÷ (s(s + 4)) (type 1), unity feedback.

  • Step: e_ss = 0.
  • Ramp: K_v = lim s × 20/(s(s + 4)) = 20/4 = 5, so e_ss = 0.2 (for a unit ramp).
  • Parabola: K_a = 0, error infinite.

For a ramp input of 3 rad/s (a radar dish tracking a target), the lag is 3 × 0.2 = 0.6 rad behind.

Worked example: type 0

G(s) = 50 ÷ ((s + 2)(s + 5)): K_p = 50/10 = 5; step error = 1/6 = 0.167 (16.7%). Raising the gain to reduce this error lowers the damping, so a PI controller is often better.

Disturbance error

For a constant disturbance entering before the plant, a type 1 controller (integral action) is needed to remove its steady-state effect; an integrator in the plant after the disturbance does not do it.

Non-unity feedback

Convert to an equivalent unity feedback system first: G_e = G ÷ (1 + GH − G), or work directly with E = R − C.

Exams usually ask

  • Determine the system type and error constants, and the steady-state error for step, ramp and parabolic inputs.
  • Find the gain needed to meet a steady-state error specification, and check stability.

Common mistake

Using the closed-loop transfer function in the error-constant formulas. They use the open-loop G(s).

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All MEG 502 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.