UNIHIVE

Study Hub UNIPORT MEG 312

MEG 312 · Mechanics of Machines

Vibrations in machines

Free, damped and forced vibration of a single-degree system, resonance and critical speeds.

Our notes

2 min read

Why it matters

Every machine vibrates. Too much vibration loosens joints, fatigues shafts and frames, wears bearings and makes noise. The key danger is resonance: forcing at a natural frequency.

The single-degree-of-freedom model

A mass m on a spring of stiffness k with a damper c: m x″ + c x′ + k x = F(t).

  • Natural frequency: ωₙ = √(k/m) rad/s; fₙ = ωₙ/2π Hz.
  • Damping ratio: ζ = c/(2√(km)). ζ < 1 underdamped (oscillates), ζ = 1 critical, ζ > 1 overdamped.
  • Damped frequency: ω_d = ωₙ√(1 − ζ²).

Worked example: free vibration

m = 10 kg, k = 40 kN/m, c = 200 N·s/m.

  1. ωₙ = √(40,000/10) = 63.2 rad/s, so fₙ = 10.1 Hz
  2. ζ = 200/(2√(40,000 × 10)) = 200/1,265 = 0.158
  3. ω_d = 63.2 × √(1 − 0.025) = 62.4 rad/s

Forced vibration

With a force F₀ sin ωt, the steady amplitude is
X = (F₀/k) / √((1 − r²)² + (2ζr)²), with r = ω/ωₙ.

  • r ≪ 1: X ≈ F₀/k (static deflection).
  • r = 1: resonance; X = (F₀/k)/(2ζ), limited only by damping.
  • r ≫ 1: X becomes small (the mass cannot follow).

Example (same system): F₀ = 100 N at ω = 50 rad/s. r = 0.791. Static deflection 2.5 mm. X = 2.5/√((1 − 0.625)² + (0.250)²) = 2.5/0.451 = 5.5 mm: more than double, because it is close to resonance.

Unbalance and isolation

A rotating unbalance m_e e gives F₀ = m_e e ω². Machine mounts isolate vibration only when r > √2: put machines on soft mounts so that the running speed is well above the mount's natural frequency.

Whirling and critical speeds of shafts

A shaft with a disc whirls violently when its speed equals its lateral natural frequency, the critical speed: N_c = (60/2π)√(k/m). For the system above, N_c = 604 rpm. Shafts run well below the first critical speed, or pass through it quickly.

Torsional vibration

Shafts with discs also twist back and forth: for two rotors on a shaft, there is a node (point of no twist) between them. Important in engines, pumps and gear trains.

Condition monitoring

Vibration measurement (accelerometers, spectra) is the main way industry spots unbalance, misalignment, looseness and bearing faults early.

Exams usually ask

  • Find natural frequency, damping ratio and damped frequency.
  • Find the forced amplitude, or the critical speed of a shaft.

Common mistake

Mixing rad/s and Hz. ωₙ = √(k/m) is in rad/s; divide by 2π for Hz and multiply by 60/2π for rpm.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All MEG 312 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.