UNIHIVE

Study Hub UNIPORT MEG 312

MEG 312 · Mechanics of Machines

Hydrostatic bearings

Bearings fed by pressurised oil, the step pad, load, flow and pump power.

Our notes

2 min read

The idea

In a hydrostatic bearing an external pump forces oil at high pressure into a recess (pocket) in the bearing. The oil lifts the load and flows out through the narrow gap at the edges. The surfaces are separated even at zero speed.

Where they are used

Large slow machines that must start under load or never touch: telescope mounts, machine-tool slides and spindles, rolling-mill necks, turbine generator start-up (jacking oil), and heavy turntables.

Advantages and drawbacks

ForAgainst
Full film at any speed, even zeroNeeds a pump, filter and supply system
Very low friction and almost no wearPumping power and cost
High stiffness and accuracyFails if the supply fails (needs back-up)

The circular step (pocket) pad

A pad of outer radius R with a central recess of radius R₀ at pressure p₀. Oil flows radially out through the gap h. The pressure is p₀ over the recess and falls logarithmically to zero at R.

  • Load: W = π p₀ (R² − R₀²) / (2 ln(R/R₀))
  • Oil flow: Q = π p₀ h³ / (6 μ ln(R/R₀))
  • Pump power: P = p₀ Q

Worked example

R = 100 mm, R₀ = 50 mm, recess pressure 2 MPa, film 0.05 mm, oil 0.05 Pa·s.

  1. ln(R/R₀) = ln 2 = 0.693
  2. W = π × 2 × 10⁶ × (0.01 − 0.0025) / (2 × 0.693) = 34.0 kN
  3. Q = π × 2 × 10⁶ × (0.05 × 10⁻³)³ / (6 × 0.05 × 0.693) = 3.78 × 10⁻⁶ m³/s = 0.227 L/min
  4. Pump power = 2 × 10⁶ × 3.78 × 10⁻⁶ = 7.6 W

Check: the average pressure over the whole pad is 34,000/(π × 0.1²) = 1.08 MPa, between zero and p₀ as it should be.

Why the flow depends on h³

Flow rises with the cube of the gap. Halving the film thickness cuts the flow to one eighth. This is what gives stiffness: if load rises and h falls, flow drops sharply and, with a restrictor (capillary or orifice) between pump and pocket, the pocket pressure rises to resist.

Restrictors

  • Capillary: a long thin tube; flow ∝ pressure drop.
  • Orifice: flow ∝ √(pressure drop).
  • Constant-flow valve or one pump per pocket: the stiffest.

Hybrid bearings

Many large bearings combine hydrostatic lift for starting and stopping with hydrodynamic action at speed.

Exams usually ask

  • Compare hydrostatic and hydrodynamic bearings.
  • Find the load, flow and pump power of a step pad.

Common mistake

Using the recess pressure times the whole pad area as the load. The pressure falls across the land, so use the formula (here about half of p₀πR²).