Vapour power cycles: Rankine and its modifications

The ideal Rankine cycle with steam tables, pump and turbine work, efficiency and quality, effects of pressure and temperature, reheat and regeneration, and real plants.

Our notes

2 min read

Why not Carnot with steam

A Carnot vapour cycle would compress a wet mixture (hard on pumps) and expand to very wet steam (erodes turbine blades). The Rankine cycle condenses fully and pumps liquid.

The ideal Rankine cycle

1-2 pump (isentropic, liquid); 2-3 boiler (constant P: heat in, to superheated steam); 3-4 turbine (isentropic); 4-1 condenser (constant P: heat out).
w_p = v₁(P₂ − P₁); w_t = h₃ − h₄; q_in = h₃ − h₂; η = (w_t − w_p) ÷ q_in.

Worked example

Boiler 4 MPa, 400 °C; condenser 10 kPa.

  • State 1 (saturated liquid, 10 kPa): h₁ = 191.83 kJ/kg, v₁ = 0.00101 m³/kg.
  • Pump: w_p = 0.00101 × (4,000 − 10) ≈ 4.03 kJ/kg; h₂ = 195.86.
  • State 3: h₃ = 3,213.6 kJ/kg, s₃ = 6.7690 kJ/kg·K.
  • State 4 (10 kPa, s₄ = s₃): x₄ = (6.7690 − 0.6493) ÷ 7.5009 ≈ 0.816; h₄ = 191.83 + 0.816 × 2,392.8 ≈ 2,144.0.
  • w_t = 3,213.6 − 2,144.0 = 1,069.6; w_net = 1,065.6; q_in = 3,213.6 − 195.9 = 3,017.7.
  • η ≈ 35.3%. Carnot between 673 K and 319 K (45.8 °C) would be 52.6%.

Check: back work ratio = 4.03/1,069.6 ≈ 0.4%, tiny compared with a gas turbine ✓; x₄ = 0.816 is wetter than the 0.88-0.90 turbines like, which is why reheat is used.

Improving efficiency

  • Lower condenser pressure (lower average heat rejection temperature), limited by cooling water temperature (warm in the tropics).
  • Superheat to higher temperature (limited by metallurgy, about 600-620 °C) and raise boiler pressure (supercritical units above 22.06 MPa).
  • Reheat: expand partly, reheat, expand again: keeps exhaust drier, raises average heat-addition temperature.
  • Regeneration with feedwater heaters (open or closed), using bled steam: raises the temperature at which heat enters.

Real plants

Losses in turbines (η_t about 85-90%), pumps, pipes, boilers. Modern coal or gas steam plants reach about 40-45%. Egbin (Lagos, 1,320 MW) is a gas-fired steam plant; refineries and fertiliser plants use steam turbines to drive compressors and pumps.

Exams usually ask: sketch the Rankine cycle on T-s; compute works, heat and efficiency with steam tables; explain the effect of boiler and condenser pressure and superheat; analyse reheat and regenerative cycles.

Common mistake: forgetting the pump work when finding h₂ (q_in = h₃ − h₁ is wrong). It is small but should be included.