Helmholtz and Gibbs functions and property relations

The Gibbs equations, Helmholtz and Gibbs functions, Maxwell relations, the Clapeyron equation, general relations for du, dh, ds and cp − cv, and the Joule-Thomson coefficient.

Our notes

2 min read

The Gibbs equations

du = T ds − P dv; dh = T ds + v dP.

Helmholtz and Gibbs functions

  • Helmholtz function a = u − Ts: da = −s dT − P dv. At constant T, the decrease in a is the maximum work a closed system can do.
  • Gibbs function g = h − Ts: dg = −s dT + v dP. At constant T and P, systems move towards minimum g; at phase equilibrium g is equal in both phases (g_f = g_g); in reactions ΔG decides direction.

Maxwell relations (from exact differentials)

  • (∂T/∂v)_s = −(∂P/∂s)_v
  • (∂T/∂P)_s = (∂v/∂s)_P
  • (∂s/∂v)_T = (∂P/∂T)_v
  • (∂s/∂P)_T = −(∂v/∂T)_P

They let us find entropy changes from measurable P-v-T data.

The Clapeyron equation

For a phase change: (dP/dT)_sat = h_fg ÷ (T v_fg). Clausius-Clapeyron (vapour as ideal gas, v_f small): ln(P₂/P₁) ≈ (h_fg/R)(1/T₁ − 1/T₂).

Worked example

Water at 100 °C: h_fg = 2,257 kJ/kg, v_fg ≈ 1.6719 m³/kg.
dP/dT = 2,257 ÷ (373.15 × 1.6719) ≈ 3.62 kPa/K.
Check from tables: P_sat is about 84.6 kPa at 95 °C and 120.9 kPa at 105 °C: (120.9 − 84.6) ÷ 10 ≈ 3.63 kPa/K ✓.

General relations

  • c_p − c_v = −T (∂v/∂T)²_P (∂P/∂v)_T = T v β² ÷ κ (β expansivity, κ isothermal compressibility). For an ideal gas this gives R; for liquids and solids it is small, so c_p ≈ c_v.
  • Joule-Thomson coefficient μ = (∂T/∂P)_h: the temperature change on throttling. μ > 0 means cooling on expansion (below the inversion temperature): the basis of gas liquefaction and of cooling across chokes in gas wells (and hydrate formation in pipelines, a petroleum engineering concern). For an ideal gas μ = 0.

Exams usually ask: define the Helmholtz and Gibbs functions and their meaning; derive a Maxwell relation; apply the Clapeyron equation; explain the Joule-Thomson effect.

Common mistake: using the Clausius-Clapeyron form (ideal vapour) near the critical point, where v_f is no longer small and the vapour is not ideal.