Introduction to turbomachinery and cavitation

Pumps, turbines and fans, Euler's equation, velocity triangles, performance and similarity laws, and cavitation with NPSH.

Our notes

2 min read

Turbomachines

Machines that transfer energy between a rotor (with blades) and a flowing fluid.

  • Absorb power (raise fluid energy): pumps, fans, compressors.
  • Produce power: turbines (water, steam, gas, wind).
  • By flow direction: radial (centrifugal pumps, Francis turbines), axial (propeller pumps, Kaplan turbines, jet engine compressors), mixed.

Euler's turbomachine equation

From the angular momentum principle: specific work w = U₂V_w2 − U₁V_w1 (U the blade speed, V_w the whirl, i.e. tangential component of the absolute velocity). For a pump with no inlet whirl: H = U₂V_w2/g.
Velocity triangles at inlet and outlet relate the absolute velocity V, blade velocity U and relative velocity W (V = U + W).

Pump performance

Hydraulic power = ρgQH; shaft power = ρgQH/η.
Example. A pump delivers 0.05 m³/s against 30 m with η = 75%: P = 1000 × 9.81 × 0.05 × 30/0.75 = 19.6 kW.
Performance curves: H, η and power against Q at fixed speed; the best efficiency point (BEP).

Similarity (affinity) laws

For the same pump (or geometrically similar pumps) at different speeds N:
Q ∝ N, H ∝ N², P ∝ N³ (and with diameter D: Q ∝ ND³, H ∝ N²D², P ∝ N³D⁵).
Example. The pump above at 1450 rev/min is run at 1740 rev/min (ratio 1.2): Q = 0.06 m³/s, H = 43.2 m, P = 19.6 × 1.728 = 33.9 kW.

Specific speed N_s = N√Q/H^(3/4) helps choose the type: low N_s centrifugal, high N_s axial.

Turbines

TurbineTypeHead
PeltonImpulse (jets on buckets)High
FrancisReaction, radial-mixedMedium (Kainji and Jebba use Francis turbines)
KaplanReaction, axial, adjustable bladesLow

Cavitation

When local pressure falls below the liquid's vapour pressure, vapour bubbles form and then collapse violently in higher-pressure regions, causing noise, vibration, loss of performance and pitting erosion of impellers and propellers.

Net positive suction head (NPSH):
NPSH_A = (p_atm − p_v)/ρg − z_s − h_L,s (z_s the suction lift above the water surface, h_L,s suction-pipe losses). Cavitation is avoided when NPSH_A > NPSH_R (given by the pump maker), with a margin.
Example. Water at 20 °C (p_v = 2.34 kPa), p_atm = 101.3 kPa, suction lift 4 m, suction losses 1 m: NPSH_A = (98.96 × 10³)/(9810) − 4 − 1 = 10.09 − 5 = 5.09 m. A pump needing NPSH_R = 6 m would cavitate: lower it, shorten the suction line, or enlarge the suction pipe.

Exams usually ask: Euler's equation and velocity triangles; pump power and efficiency; affinity laws; causes, effects and prevention of cavitation with NPSH.

Common mistake: placing a pump high above the water to "help" it. Suction lift reduces NPSH available and invites cavitation; hot water makes it worse (higher vapour pressure).