MEG 301 · Fluid Mechanics II
Our notes
2 min readTurbomachines
Machines that transfer energy between a rotor (with blades) and a flowing fluid.
- Absorb power (raise fluid energy): pumps, fans, compressors.
- Produce power: turbines (water, steam, gas, wind).
- By flow direction: radial (centrifugal pumps, Francis turbines), axial (propeller pumps, Kaplan turbines, jet engine compressors), mixed.
Euler's turbomachine equation
From the angular momentum principle: specific work w = U₂V_w2 − U₁V_w1 (U the blade speed, V_w the whirl, i.e. tangential component of the absolute velocity). For a pump with no inlet whirl: H = U₂V_w2/g.
Velocity triangles at inlet and outlet relate the absolute velocity V, blade velocity U and relative velocity W (V = U + W).
Pump performance
Hydraulic power = ρgQH; shaft power = ρgQH/η.
Example. A pump delivers 0.05 m³/s against 30 m with η = 75%: P = 1000 × 9.81 × 0.05 × 30/0.75 = 19.6 kW.
Performance curves: H, η and power against Q at fixed speed; the best efficiency point (BEP).
Similarity (affinity) laws
For the same pump (or geometrically similar pumps) at different speeds N:
Q ∝ N, H ∝ N², P ∝ N³ (and with diameter D: Q ∝ ND³, H ∝ N²D², P ∝ N³D⁵).
Example. The pump above at 1450 rev/min is run at 1740 rev/min (ratio 1.2): Q = 0.06 m³/s, H = 43.2 m, P = 19.6 × 1.728 = 33.9 kW.
Specific speed N_s = N√Q/H^(3/4) helps choose the type: low N_s centrifugal, high N_s axial.
Turbines
| Turbine | Type | Head |
|---|---|---|
| Pelton | Impulse (jets on buckets) | High |
| Francis | Reaction, radial-mixed | Medium (Kainji and Jebba use Francis turbines) |
| Kaplan | Reaction, axial, adjustable blades | Low |
Cavitation
When local pressure falls below the liquid's vapour pressure, vapour bubbles form and then collapse violently in higher-pressure regions, causing noise, vibration, loss of performance and pitting erosion of impellers and propellers.
Net positive suction head (NPSH):
NPSH_A = (p_atm − p_v)/ρg − z_s − h_L,s (z_s the suction lift above the water surface, h_L,s suction-pipe losses). Cavitation is avoided when NPSH_A > NPSH_R (given by the pump maker), with a margin.
Example. Water at 20 °C (p_v = 2.34 kPa), p_atm = 101.3 kPa, suction lift 4 m, suction losses 1 m: NPSH_A = (98.96 × 10³)/(9810) − 4 − 1 = 10.09 − 5 = 5.09 m. A pump needing NPSH_R = 6 m would cavitate: lower it, shorten the suction line, or enlarge the suction pipe.
Exams usually ask: Euler's equation and velocity triangles; pump power and efficiency; affinity laws; causes, effects and prevention of cavitation with NPSH.
Common mistake: placing a pump high above the water to "help" it. Suction lift reduces NPSH available and invites cavitation; hot water makes it worse (higher vapour pressure).
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Turbomachinery
(opens en.wikipedia.org in a new tab)
Wikipedia, Turbomachinery, CC BY-SA 4.0 · licence
-
Centrifugal pump
(opens en.wikipedia.org in a new tab)
Wikipedia, Centrifugal pump, CC BY-SA 4.0 · licence
-
Cavitation
(opens en.wikipedia.org in a new tab)
Wikipedia, Cavitation, CC BY-SA 4.0 · licence
Watch
-
Best pick Pump Cavitation Explained | Causes, Effects & Prevention | Complete HVAC Pump Tutorial
22 min · ≈ 99 MB · about ₦56
(opens youtube.com in a new tab)
-
Pump Cavitation & Net Positive Suction Head Basics I NPSH Derivation
22 min · ≈ 99 MB · about ₦56
(opens youtube.com in a new tab)
-
NPSH & Cavitation Explained | The Real Reason Pumps Get Damaged
4 min · ≈ 18 MB · about ₦10
(opens youtube.com in a new tab)
-
Turbo Machinery Lecture | Pumps, Turbines, Cavitation, NPSH, Specific Speed & Fluid Machines
1 h 21 min · ≈ 365 MB · about ₦205
(opens youtube.com in a new tab)
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.