UNIHIVE

Study Hub UNIPORT MEG 252

MEG 252 · Machine Drawing II

The ISO system of limits and fits

Basic size, deviations, tolerance grades, hole-basis and shaft-basis systems, with worked fit calculations.

Our notes

2 min read

Why tolerances

No part can be made to an exact size. A tolerance is the permitted variation. Too tight is expensive; too loose fails to work.

Terms

  • Basic (nominal) size: the size from which limits are set (e.g. Ø25).
  • Upper and lower limits: the largest and smallest allowed sizes.
  • Tolerance = upper limit − lower limit.
  • Deviation: limit minus basic size. Upper deviation (ES for holes, es for shafts) and lower deviation (EI, ei).
  • Fundamental deviation: the deviation nearest the zero line; fixed by the letter (A-Z for holes, a-z for shafts).
  • IT grade: the size of the tolerance, IT01 to IT18 (smaller number = tighter). Machining often gives IT6-IT9; reaming IT7.

The tolerance unit

For sizes up to 500 mm: i = 0.45 ∛D + 0.001D (µm), where D is the geometric mean of the size range (mm). IT6 = 10i, IT7 = 16i, IT8 = 25i...
Example: for 18-30 mm, D = √(18 × 30) = 23.24; i = 0.45 × 2.855 + 0.023 = 1.31 µm. IT7 = 16 × 1.31 = 20.9 → 21 µm; IT6 = 13.1 → 13 µm. These match the ISO table values.

Kinds of fit

  • Clearance fit: always a gap (running shafts).
  • Interference fit: always overlap (pressed-in bushes, gears on shafts).
  • Transition fit: may be either (locating fits).

Hole-basis and shaft-basis systems

  • Hole basis: the hole is always H (lower deviation 0); the shaft letter is varied to get the fit. Preferred, because holes are made with standard drills and reamers and checked with standard plug gauges.
  • Shaft basis: the shaft is always h (upper deviation 0); used when one bright-drawn shaft carries several parts with different fits.

Worked examples (basic size 25 mm; values from ISO 286 tables)

1. Ø25 H7/g6 (close running clearance fit)

  • Hole H7: 25.000 to 25.021.
  • Shaft g6: fundamental deviation es = −0.007; tolerance 0.013 → 24.980 to 24.993.
  • Maximum clearance = 25.021 − 24.980 = 0.041 mm; minimum clearance = 25.000 − 24.993 = 0.007 mm. Always a clearance. ✓

2. Ø25 H7/k6 (transition fit)

  • Shaft k6: ei = +0.002 → 25.002 to 25.015.
  • Maximum clearance = 25.021 − 25.002 = 0.019 mm; maximum interference = 25.015 − 25.000 = 0.015 mm. Either can happen: transition. ✓

3. Ø25 H7/p6 (press fit)

  • Shaft p6: ei = +0.022 → 25.022 to 25.035.
  • Minimum interference = 25.022 − 25.021 = 0.001 mm; maximum = 25.035 − 25.000 = 0.035 mm. Always interference. ✓

Common preferred fits (hole basis)

H11/c11 loose running; H9/d9 free running; H8/f7 close running; H7/g6 sliding; H7/h6 locational clearance; H7/k6 locational transition; H7/n6 locational transition (tighter); H7/p6 locational interference; H7/s6 medium drive; H7/u6 force fit.

Exams usually ask

  • Define tolerance, allowance, deviation and fit.
  • Work out limits, clearances and interferences from tables.
  • Compare hole-basis and shaft-basis systems.

Common mistake

Reading the letter as the tolerance size. The letter fixes the position (fundamental deviation); the number fixes the size of the tolerance.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All MEG 252 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.