MEG 252 · Machine Drawing II
Our notes
2 min readWhy tolerances
No part can be made to an exact size. A tolerance is the permitted variation. Too tight is expensive; too loose fails to work.
Terms
- Basic (nominal) size: the size from which limits are set (e.g. Ø25).
- Upper and lower limits: the largest and smallest allowed sizes.
- Tolerance = upper limit − lower limit.
- Deviation: limit minus basic size. Upper deviation (ES for holes, es for shafts) and lower deviation (EI, ei).
- Fundamental deviation: the deviation nearest the zero line; fixed by the letter (A-Z for holes, a-z for shafts).
- IT grade: the size of the tolerance, IT01 to IT18 (smaller number = tighter). Machining often gives IT6-IT9; reaming IT7.
The tolerance unit
For sizes up to 500 mm: i = 0.45 ∛D + 0.001D (µm), where D is the geometric mean of the size range (mm). IT6 = 10i, IT7 = 16i, IT8 = 25i...
Example: for 18-30 mm, D = √(18 × 30) = 23.24; i = 0.45 × 2.855 + 0.023 = 1.31 µm. IT7 = 16 × 1.31 = 20.9 → 21 µm; IT6 = 13.1 → 13 µm. These match the ISO table values.
Kinds of fit
- Clearance fit: always a gap (running shafts).
- Interference fit: always overlap (pressed-in bushes, gears on shafts).
- Transition fit: may be either (locating fits).
Hole-basis and shaft-basis systems
- Hole basis: the hole is always H (lower deviation 0); the shaft letter is varied to get the fit. Preferred, because holes are made with standard drills and reamers and checked with standard plug gauges.
- Shaft basis: the shaft is always h (upper deviation 0); used when one bright-drawn shaft carries several parts with different fits.
Worked examples (basic size 25 mm; values from ISO 286 tables)
1. Ø25 H7/g6 (close running clearance fit)
- Hole H7: 25.000 to 25.021.
- Shaft g6: fundamental deviation es = −0.007; tolerance 0.013 → 24.980 to 24.993.
- Maximum clearance = 25.021 − 24.980 = 0.041 mm; minimum clearance = 25.000 − 24.993 = 0.007 mm. Always a clearance. ✓
2. Ø25 H7/k6 (transition fit)
- Shaft k6: ei = +0.002 → 25.002 to 25.015.
- Maximum clearance = 25.021 − 25.002 = 0.019 mm; maximum interference = 25.015 − 25.000 = 0.015 mm. Either can happen: transition. ✓
3. Ø25 H7/p6 (press fit)
- Shaft p6: ei = +0.022 → 25.022 to 25.035.
- Minimum interference = 25.022 − 25.021 = 0.001 mm; maximum = 25.035 − 25.000 = 0.035 mm. Always interference. ✓
Common preferred fits (hole basis)
H11/c11 loose running; H9/d9 free running; H8/f7 close running; H7/g6 sliding; H7/h6 locational clearance; H7/k6 locational transition; H7/n6 locational transition (tighter); H7/p6 locational interference; H7/s6 medium drive; H7/u6 force fit.
Exams usually ask
- Define tolerance, allowance, deviation and fit.
- Work out limits, clearances and interferences from tables.
- Compare hole-basis and shaft-basis systems.
Common mistake
Reading the letter as the tolerance size. The letter fixes the position (fundamental deviation); the number fixes the size of the tolerance.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Engineering fit
(opens en.wikipedia.org in a new tab)
Wikipedia, Engineering fit, CC BY-SA 4.0 · licence
-
Engineering tolerance
(opens en.wikipedia.org in a new tab)
Wikipedia, Engineering tolerance, CC BY-SA 4.0 · licence
Watch
-
Best pick The Genius System of Limits and Fits
12 min · ≈ 54 MB · about ₦30
(opens youtube.com in a new tab)
-
LIMITS FITS AND TOLERANCES: What is limit fit & tolerance and its need? Animation
7 min · ≈ 32 MB · about ₦18
(opens youtube.com in a new tab)
-
Tolerance, Limits and Fits with example
5 min · ≈ 23 MB · about ₦13
(opens youtube.com in a new tab)
-
Engineering tolerances - Fits (ISO)
13 min · ≈ 59 MB · about ₦33
(opens youtube.com in a new tab)
-
Terminologies of limits fits and tolerances
42 min · ≈ 189 MB · about ₦106
(opens youtube.com in a new tab)
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.