Principle

Pass a known current I into the ground through two current electrodes (A, B) and measure the potential difference ΔV between two potential electrodes (M, N). From I, ΔV and the electrode geometry, compute the apparent resistivity ρ_a: the resistivity a uniform ground would need to give the same reading. Over layered ground, ρ_a varies with electrode spacing because current reaches deeper as spacing grows.
ρ_a = K (ΔV / I), where K is the geometric factor for the array.

Common arrays

  • Wenner: AMNB equally spaced at a: K = 2πa. Simple, good signal; all four electrodes move.
  • Schlumberger: MN small, AB large; AB/2 = L, MN/2 = l: K = π (L² − l²) / (2l). Only A and B move for most readings: faster for soundings, less affected by near-surface changes at M and N.
  • Dipole-dipole: good for lateral changes and 2-D imaging; weaker signals.
  • Pole-pole, pole-dipole, gradient arrays for special purposes.

Worked examples

  • Wenner, a = 10 m, ΔV/I = 1.5 Ω: ρ_a = 2π × 10 × 1.5 = 94.2 Ω m.
  • Schlumberger, L = 50 m, l = 2 m, ΔV/I = 0.1 Ω: K = π(2,500 − 4)/4 = 1,960.4 m; ρ_a = 196 Ω m.

(Checked by computer.)

Vertical electrical sounding (VES)

Expand the electrodes about a fixed centre (AB/2 from about 1 m to hundreds of metres) and plot ρ_a against AB/2 on log-log paper. The curve shows layers:

  • H-type (ρ₁ > ρ₂ < ρ₃): a conductive middle layer: e.g. dry topsoil, saturated weathered layer (aquifer), resistive fresh basement: the classic basement aquifer curve.
  • K-type (ρ₁ < ρ₂ > ρ₃), A-type (increasing), Q-type (decreasing).

Interpret by curve matching with master curves or by computer inversion (giving layer resistivities and thicknesses), checked against borehole logs.
Equivalence: different combinations of thickness and resistivity can give the same curve (e.g. a thin, very conductive layer and a thicker, less conductive one), and suppression: a thin layer with intermediate resistivity may not show at all.

Profiling and 2-D imaging (ERT)

  • Constant-separation traversing: fixed spacing moved along a line maps lateral changes (fractures, contacts).
  • Electrical resistivity tomography: many electrodes along a line, switched automatically, giving a pseudosection that is inverted to a 2-D (or 3-D) image of resistivity: fractured zones, clay lenses, contamination plumes, saline intrusion.

Practical points

  • Good electrode contact (water the electrodes in dry season; the Niger Delta's high water table helps).
  • Lines away from metal fences, pipes and power lines.
  • Stack readings and reverse current to cancel natural potentials.

Uses

Groundwater exploration (the most common use in Nigeria: siting boreholes in basement areas and finding fresh water above saline zones in the coastal sediments), depth to bedrock, clay for bricks and dams, sand and gravel, landfill leachate and oil spill impact studies, foundation studies, and earthing design.

Exams usually ask

  • Derive or apply the geometric factor for Wenner or Schlumberger arrays.
  • Describe a VES survey and interpret curve types.
  • Explain equivalence and suppression.

Common mistake

Reading apparent resistivity as the true resistivity of a layer at depth AB/2. It is an average response; true values and depths come only from interpretation.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.