UNIHIVE

Study Hub UNIPORT FSB 201.1

FSB 201.1 · Cell Biology

How cells are studied

Light and electron microscopes, magnification and resolution, staining, and cell fractionation.

Our notes

2 min read

Magnification and resolution

  • Magnification: how many times bigger the image is than the object.
  • Resolution: the smallest distance between two points that can still be seen as separate. A bigger image without better resolution is just blurred.
  • Magnification = image size ÷ actual size.

Light microscope

Uses visible light and glass lenses. Total magnification = eyepiece × objective (10 × 40 = 400). Resolution limit about 0.2 µm, set by the wavelength of light. Living cells can be seen; stains (iodine, methylene blue, haematoxylin and eosin) add contrast. Phase-contrast and fluorescence microscopes are variations; confocal microscopes give sharp optical slices.

Electron microscopes

Use a beam of electrons with a much shorter wavelength; magnets act as lenses; the specimen is in a vacuum, so it must be dead.

  • Transmission EM (TEM): electrons pass through very thin sections; resolution about 0.1 to 1 nm; shows internal structure (ribosomes, membranes).
  • Scanning EM (SEM): electrons bounce off a metal-coated surface; gives 3-D surface pictures; resolution about 3 to 10 nm.
  • Artefacts: features made by preparation (fixing, cutting, staining) and not present in the living cell.

Units

1 mm = 1,000 µm; 1 µm = 1,000 nm. Most animal cells are 10 to 30 µm; bacteria 1 to 5 µm; ribosomes about 20 to 30 nm.

Worked example: actual size

A mitochondrion is 12 mm long in an electron micrograph at × 6,000. Actual size = 12 mm ÷ 6,000 = 0.002 mm = 2 µm.

Worked example: eyepiece graticule

At × 400, one eyepiece division equals 2.5 µm (found with a stage micrometer). A cell spans 16 divisions: length = 16 × 2.5 = 40 µm.

Cell fractionation

To study organelles, cells are broken open and the parts separated:

  1. Homogenisation in a cold, isotonic, buffered solution (cold slows enzymes; isotonic stops organelles bursting; buffer keeps pH).
  2. Filtration removes debris.
  3. Differential centrifugation: spinning at higher and higher speeds. Heavy parts settle first: nuclei, then mitochondria and chloroplasts, then lysosomes, then microsomes (ER pieces) and ribosomes.

Other tools

  • Cell culture: growing cells outside the body.
  • Autoradiography: radioactive tracers show where molecules go.
  • Immunofluorescence: labelled antibodies light up chosen proteins.

Exams usually ask

  • Compare light and electron microscopes (TEM and SEM).
  • Magnification calculations; describe cell fractionation and explain each condition.

Common mistake

Confusing magnification with resolution: magnifying beyond the resolution limit shows no new detail.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All FSB 201.1 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.