ENG 301 · Engineering Mathematics IV (Probability and Statistics)
Our notes
2 min readDefinitions
For the lifetime T of a component:
- Failure distribution F(t) = P(T ≤ t); failure density f(t) = F′(t).
- Reliability R(t) = P(T > t) = 1 − F(t).
- Hazard function (failure rate) h(t) = f(t)/R(t): the rate of failure at time t among items still working. R(t) = exp(−∫₀ᵗ h(u) du).
- Mean time to failure: MTTF = ∫₀^∞ R(t) dt (= E[T]).
Constant failure rate
h(t) = λ gives R(t) = e^(−λt) and MTTF = 1/λ (the exponential model).
Worked example. λ = 2 × 10⁻⁵ per hour. MTTF = 50,000 h. R(1 year = 8,760 h) = e^(−0.175) = 0.839.
The bathtub curve
- Infant mortality (falling h): manufacturing defects; removed by burn-in testing.
- Useful life (roughly constant h): random failures; exponential model.
- Wear-out (rising h): fatigue, corrosion, insulation ageing; planned replacement.
The Weibull shape β < 1, = 1, > 1 matches the three stages.
Systems
- Series (all parts must work): R = R₁R₂…Rₙ. With exponential parts, rates add: λ_s = Σλᵢ, MTTF = 1/Σλᵢ.
- Parallel / redundant (works if at least one works): R = 1 − (1 − R₁)(1 − R₂)…(1 − Rₙ).
Worked example. Three components each with R = 0.9. Series: 0.9³ = 0.729. Parallel: 1 − 0.1³ = 0.999.
Worked example. Two identical exponential units in active parallel: MTTF = 1/λ + 1/(2λ) = 1.5/λ (redundancy adds 50%, not 100%).
- Series-parallel: reduce step by step (combine parallel blocks, then multiply series blocks).
- k-out-of-n: works if at least k of n work (binomial sum): 2-out-of-3 with R = 0.9 each: 3(0.9²)(0.1) + 0.9³ = 0.243 + 0.729 = 0.972.
- Standby redundancy (spare switched in on failure, perfect switch): MTTF = 2/λ for two units, better than active parallel.
Availability
For repairable systems:
Availability A = MTTF/(MTTF + MTTR) (MTTR = mean time to repair; for repairable items MTBF is used for MTTF).
Worked example. A generator runs on average 990 hours between failures and takes 10 hours to repair: A = 990/1,000 = 0.99, about 88 hours down a year. Markov models (later topic) give the same answer, A = μ/(λ + μ).
Exams usually ask: define R(t), f(t), h(t) and MTTF and relate them; derive R(t) for constant hazard; draw and explain the bathtub curve; series, parallel and mixed system reliability; MTTF of redundant systems; availability.
Common mistake: adding reliabilities for parallel parts (0.9 + 0.9 = 1.8). Work with failure probabilities: R = 1 − (0.1)(0.1) = 0.99.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Best pick NIST Engineering Statistics Handbook: Basic terms and models for reliability
(opens itl.nist.gov in a new tab)
-
NIST Engineering Statistics Handbook: Repairable systems and lifetime distribution models
(opens itl.nist.gov in a new tab)
-
NIST Engineering Statistics Handbook: Failure (hazard) rate
(opens itl.nist.gov in a new tab)
-
NIST Engineering Statistics Handbook: The bathtub curve
(opens itl.nist.gov in a new tab)
-
NIST Engineering Statistics Handbook: Exponential lifetime model
(opens itl.nist.gov in a new tab)
-
Failure rate
(opens en.wikipedia.org in a new tab)
Wikipedia, Failure rate, CC BY-SA 4.0 · licence
-
Reliability engineering
(opens en.wikipedia.org in a new tab)
Wikipedia, Reliability engineering, CC BY-SA 4.0 · licence
-
Bathtub curve
(opens en.wikipedia.org in a new tab)
Wikipedia, Bathtub curve, CC BY-SA 4.0 · licence
We link to free material and never copy it. Every link was opened by our team before it went up.