Reliability, failure density and the hazard function

Reliability function, failure density, hazard (failure) rate and the bathtub curve, mean time to failure, series and parallel systems, and availability.

Our notes

2 min read

Definitions

For the lifetime T of a component:

  • Failure distribution F(t) = P(T ≤ t); failure density f(t) = F′(t).
  • Reliability R(t) = P(T > t) = 1 − F(t).
  • Hazard function (failure rate) h(t) = f(t)/R(t): the rate of failure at time t among items still working. R(t) = exp(−∫₀ᵗ h(u) du).
  • Mean time to failure: MTTF = ∫₀^∞ R(t) dt (= E[T]).

Constant failure rate

h(t) = λ gives R(t) = e^(−λt) and MTTF = 1/λ (the exponential model).
Worked example. λ = 2 × 10⁻⁵ per hour. MTTF = 50,000 h. R(1 year = 8,760 h) = e^(−0.175) = 0.839.

The bathtub curve

  1. Infant mortality (falling h): manufacturing defects; removed by burn-in testing.
  2. Useful life (roughly constant h): random failures; exponential model.
  3. Wear-out (rising h): fatigue, corrosion, insulation ageing; planned replacement.

The Weibull shape β < 1, = 1, > 1 matches the three stages.

Systems

  • Series (all parts must work): R = R₁R₂…Rₙ. With exponential parts, rates add: λ_s = Σλᵢ, MTTF = 1/Σλᵢ.
  • Parallel / redundant (works if at least one works): R = 1 − (1 − R₁)(1 − R₂)…(1 − Rₙ).

Worked example. Three components each with R = 0.9. Series: 0.9³ = 0.729. Parallel: 1 − 0.1³ = 0.999.
Worked example. Two identical exponential units in active parallel: MTTF = 1/λ + 1/(2λ) = 1.5/λ (redundancy adds 50%, not 100%).

  • Series-parallel: reduce step by step (combine parallel blocks, then multiply series blocks).
  • k-out-of-n: works if at least k of n work (binomial sum): 2-out-of-3 with R = 0.9 each: 3(0.9²)(0.1) + 0.9³ = 0.243 + 0.729 = 0.972.
  • Standby redundancy (spare switched in on failure, perfect switch): MTTF = 2/λ for two units, better than active parallel.

Availability

For repairable systems:
Availability A = MTTF/(MTTF + MTTR) (MTTR = mean time to repair; for repairable items MTBF is used for MTTF).
Worked example. A generator runs on average 990 hours between failures and takes 10 hours to repair: A = 990/1,000 = 0.99, about 88 hours down a year. Markov models (later topic) give the same answer, A = μ/(λ + μ).

Exams usually ask: define R(t), f(t), h(t) and MTTF and relate them; derive R(t) for constant hazard; draw and explain the bathtub curve; series, parallel and mixed system reliability; MTTF of redundant systems; availability.

Common mistake: adding reliabilities for parallel parts (0.9 + 0.9 = 1.8). Work with failure probabilities: R = 1 − (0.1)(0.1) = 0.99.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

We link to free material and never copy it. Every link was opened by our team before it went up.

All ENG 301 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.