ENG 209 · Basic Thermodynamics and Heat Transfer
Our notes
2 min readOverall heat transfer coefficient
For heat flowing from a fluid, through a wall, into another fluid, the resistances add:
1/U = 1/h_i + L/k + 1/h_o (plane wall, per m²), and Q̇ = UAΔT_overall.
Example. Room air (h_i = 10), a 0.2 m brick wall (k = 0.7), outside air (h_o = 25):
1/U = 0.1 + 0.2857 + 0.04 = 0.4257 → U = 2.35 W/m²·K. For 10 m² and a 20 K difference: Q̇ = 2.35 × 10 × 20 = 470 W (less than the 700 W for the bare wall faces, because the air films add resistance).
Combined convection and radiation
A hot surface loses heat both ways in parallel: Q̇ = (h_conv + h_rad) A ΔT, with h_rad = εσ(T_s² + T_∞²)(T_s + T_∞). For a pipe at 80 °C in a room, radiation can be as large as free convection.
Insulation
- Adds resistance; chosen by k, temperature limit, cost, moisture behaviour (glass wool, rock wool, polyurethane foam, calcium silicate).
- Critical radius of insulation for a pipe: r_c = k/h. Adding insulation to a pipe smaller than r_c actually increases heat loss (the outer surface area grows faster than the resistance). For k = 0.05 and h = 10: r_c = 5 mm. Electrical cables use this to shed heat.
- Increasing heat transfer: fins (extended surfaces) on motorbike engines and radiators.
Heat exchangers
| Type | Description |
|---|---|
| Double-pipe | One pipe inside another; simple |
| Shell-and-tube | Many tubes inside a shell, with baffles; oil and power plants |
| Plate | Thin corrugated plates; compact, easy to clean (food, dairy) |
| Compact / finned | Car radiators, air conditioners |
Flow arrangements: parallel flow (both fluids the same direction) and counterflow (opposite: more effective).
Log mean temperature difference
Q̇ = UA ΔT_lm, with ΔT_lm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the temperature differences at the two ends.
Example (counterflow). Hot oil 150 → 90 °C; cold water 30 → 70 °C. ΔT₁ = 150 − 70 = 80 K; ΔT₂ = 90 − 30 = 60 K.
ΔT_lm = 20/ln(80/60) = 20/0.2877 = 69.5 K. For Q̇ = 100 kW and U = 500 W/m²·K: A = 100 000/(500 × 69.5) = 2.88 m².
Check: the LMTD always lies between the two end differences (60 < 69.5 < 80) ✓.
Fouling
Deposits (scale, rust, oil) add a fouling resistance and lower U over time: exchangers are cleaned on a schedule.
Exams usually ask: overall U of a wall or pipe; critical insulation radius; LMTD and exchanger area; parallel versus counterflow.
Common mistake: using the arithmetic mean temperature difference. It overestimates the heat transfer; use the log mean.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Thermal conductance and resistance
(opens en.wikipedia.org in a new tab)
Wikipedia, Thermal conductance and resistance, CC BY-SA 4.0 · licence
-
Heat exchanger
(opens en.wikipedia.org in a new tab)
Wikipedia, Heat exchanger, CC BY-SA 4.0 · licence
-
Thermal insulation
(opens en.wikipedia.org in a new tab)
Wikipedia, Thermal insulation, CC BY-SA 4.0 · licence
Watch
-
Best pick Overall Heat Transfer Coefficient - Heat Exchanger - Heat Transfer
12 min · ≈ 54 MB · about ₦30
(opens youtube.com in a new tab)
-
Heat Transfer Chapter 11.1-11.2 Heat Exchangers Types, Overall Heat Transfer Coefficient
6 min · ≈ 27 MB · about ₦15
(opens youtube.com in a new tab)
-
Overall heat transfer Coefficient
9 min · ≈ 41 MB · about ₦23
(opens youtube.com in a new tab)
-
Heat Exchanger 1 ME4313
40 min · ≈ 180 MB · about ₦101
(opens youtube.com in a new tab)
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.