Real fluid flow: viscous flow in pipes

Effects of viscosity, laminar flow between plates and in pipes, the Hagen-Poiseuille equation, and turbulent velocity profiles.

Our notes

2 min read

Real fluids

Real fluids have viscosity, so:

  • the fluid sticks to walls (no-slip condition);
  • there are velocity gradients and shear stresses;
  • mechanical energy is lost as heat (head loss).

Laminar flow in a circular pipe

For fully developed laminar flow the velocity profile is a parabola:
u = u_max (1 − r²/R²), with u_max = 2V (mean velocity V = half the centre velocity).
Wall shear stress τ_w = 8μV/D.

Hagen-Poiseuille equation

Pressure drop over length L:
Δp = 32μLV/D², or Q = πD⁴Δp/(128μL).
The flow rate depends on D⁴: halving the diameter cuts the flow sixteen-fold at the same pressure drop. In Darcy form the friction factor is f = 64/Re.

Worked example

Oil (μ = 0.1 Pa·s, ρ = 900 kg/m³) at V = 0.5 m/s in a 20 mm pipe, 10 m long.
Re = 900 × 0.5 × 0.02/0.1 = 90: laminar.
Δp = 32 × 0.1 × 10 × 0.5/(0.02)² = 40 kPa.
Check: f = 64/90 = 0.711; Δp = f (L/D)(ρV²/2) = 0.711 × 500 × 112.5 = 40 kPa ✓.

Laminar flow between parallel plates

Fixed plates, gap h: parabolic profile, Q per unit width = h³Δp/(12μL). Used for leakage past pistons and in lubrication.

Turbulent flow

Velocity fluctuates; eddies mix momentum, so the profile is flatter in the core and steeper at the wall. Approximately u/u_max = (y/R)^(1/7) (the one-seventh power law); mean velocity ≈ 0.82 u_max. Near the wall a thin viscous sublayer remains. Head loss rises roughly with V² (and depends on wall roughness).

Entrance length

Flow becomes fully developed after an entrance length L_e ≈ 0.06 Re D (laminar) or about 10-60 D (turbulent).

Measuring viscosity

  • Falling-sphere viscometer (Stokes' law, F = 3πμDV, for Re < 1).
  • Capillary tube viscometer (Hagen-Poiseuille).
  • Rotating cylinder viscometer.

Exams usually ask

  • Derive the velocity profile and Hagen-Poiseuille equation for laminar pipe flow.
  • Calculate pressure drop, flow rate and wall shear in laminar flow.
  • Compare laminar and turbulent velocity profiles.

Common mistake

Using f = 64/Re for turbulent flow. It holds only for laminar flow (Re below about 2,000); use the Moody chart or Colebrook equation otherwise.