Serial, parallel, synchronous and asynchronous transmission, and error control

Parallel versus serial, asynchronous start-stop and synchronous transmission, line coding, and error detection and correction (parity, checksums, CRC, Hamming).

Our notes

3 min read

Parallel and serial

  • Parallel: several bits at once on several wires (old printer cables, the internal buses of a computer). Fast over short distances but suffers skew (bits arriving at slightly different times) and crosstalk, and needs many wires.
  • Serial: one bit after another on one line. Used for almost all communication links (USB, SATA, PCIe lanes, Ethernet), because high-speed serial is now faster and cheaper.

Asynchronous transmission (start-stop)

Each character is sent on its own: line idle at 1 → start bit (0) → 5-8 data bits (least significant first) → optional parity bit → stop bit(s) (1). The receiver resynchronises at each start bit, so the clocks need only be roughly the same.
Worked example. At 9,600 bps with 8 data bits, no parity, 1 stop bit (8N1), each character takes 10 bits: 960 characters per second; efficiency = 8/10 = 80%.
Simple and cheap: keyboards, serial (RS-232) ports, GPS modules, Arduino-to-PC links.

Synchronous transmission

Data is sent in large blocks (frames) with no start/stop bits per character; sender and receiver keep their clocks in step using sync characters or flag patterns (01111110 in HDLC) and the transitions in the signal itself.
Worked example. A frame of 1,000 data bytes with 6 bytes of header, CRC and flags: efficiency = 1,000/1,006 = 99.4%.
Used for high-speed links (Ethernet, SONET/SDH, HDLC).

Line coding (digital data to digital signal)

CodeRuleNotes
NRZ-Lhigh = 0 (or 1), low = the othersimple; long runs lose clock sync
NRZ-Ia 1 is a transition, a 0 noneruns of 0s still a problem
Manchestertransition in the middle of every bit (low-to-high = 1 in IEEE 802.3)self-clocking; needs double the bandwidth; 10 Mbps Ethernet
Differential Manchestertransition at the start for 0token ring
Bipolar AMI0 = no pulse, 1s alternate + and −no DC component; used in T1
4B/5B, 8B/10B, 64B/66Bcode blocks with enough transitionsFast and Gigabit Ethernet, USB 3

Error detection

  • Parity bit: makes the number of 1s even (or odd). Detects any odd number of bit errors; misses errors in pairs. Two-dimensional parity (rows and columns) detects more and can correct a single error.
  • Checksum: add the data words (16-bit one's complement sum in IP, TCP and UDP); the receiver adds everything and should get all 1s.
  • Cyclic redundancy check (CRC): treat the data as a polynomial; divide (modulo-2, XOR) by an agreed generator; send the remainder with the data. The receiver divides the whole frame: a zero remainder means no detected error. Detects all single and double errors and all bursts shorter than the CRC. Ethernet uses CRC-32.

Worked example. Data 1101, generator 1011 (x³ + x + 1). Append 3 zeros: 1101000. Divide by XOR: 1101 ⊕ 1011 = 0110 → bring down 0: 1100 ⊕ 1011 = 0111 → bring down 0: 1110 ⊕ 1011 = 0101 → bring down 0: 1010 ⊕ 1011 = 0001. Remainder 001; send 1101001. Dividing 1101001 by 1011 leaves 000, so it checks.

Error correction

  • Backward error correction (ARQ): detect and ask for a resend (stop-and-wait, go-back-N, selective repeat).
  • Forward error correction (FEC): add enough redundancy to fix errors without a resend (Hamming codes, Reed-Solomon in CDs and QR codes, convolutional, turbo and LDPC codes in mobile networks). Used where resends are slow (satellite) or impossible (broadcast).
  • Hamming code: to correct one error in m data bits you need r check bits with 2ʳ ≥ m + r + 1. For m = 4: r = 3 (Hamming (7,4)); for m = 8, r = 4.

Exams usually ask: parallel versus serial; asynchronous versus synchronous with efficiency calculations; draw line codes (NRZ, Manchester) for a bit pattern; parity, checksum and CRC (work a CRC by hand); Hamming bits; ARQ versus FEC.

Common mistake: in a CRC, forgetting to append (degree of generator) zeros before dividing, or using ordinary subtraction. Modulo-2 division uses XOR and has no carries or borrows.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.