UNIHIVE

Study Hub UNIPORT CHM 235

CHM 235 · Analytical Chemistry I

Precipitation titrations

Argentometry and the Mohr, Volhard and Fajans methods, with conditions and a worked example.

Our notes

2 min read

The idea

In a precipitation titration the titrant forms an insoluble product with the analyte. The most important are argentometric titrations, which use silver nitrate (AgNO₃) to determine halides (Cl⁻, Br⁻, I⁻), thiocyanate (SCN⁻) and silver itself:
Ag⁺ + Cl⁻ → AgCl(s) (white).
The difficulty is detecting the endpoint, which gives three classic methods.

Mohr method (chromate indicator)

  • Indicator: potassium chromate (K₂CrO₄).
  • After all Cl⁻ has precipitated, the first excess Ag⁺ forms red-brown silver chromate (Ag₂CrO₄).
  • Works because AgCl is less soluble (in mol/L) than Ag₂CrO₄, so AgCl precipitates first.
  • pH must be about 6.5-10: in acid, chromate turns to dichromate (endpoint late); in strong base, Ag₂O precipitates.
  • Direct titration; used for chloride in water and food (salt in butter).
  • Needs an indicator blank correction (some Ag⁺ is needed to form visible red colour).

Volhard method (back titration)

  • Excess standard AgNO₃ is added to the halide; the leftover Ag⁺ is titrated with standard thiocyanate (KSCN or NH₄SCN): Ag⁺ + SCN⁻ → AgSCN(s).
  • Indicator: iron(III) (ferric alum); the first excess SCN⁻ forms red FeSCN²⁺.
  • Done in acid solution (nitric acid), so it works where carbonate, phosphate and similar ions would interfere with Mohr.
  • For chloride, AgCl is more soluble than AgSCN and can react with SCN⁻ (making the endpoint fade); fix: filter off AgCl or coat it with nitrobenzene before back titration. Not needed for Br⁻ and I⁻.

Fajans method (adsorption indicator)

  • Indicator: an anionic dye such as fluorescein or dichlorofluorescein.
  • Before the equivalence point, the AgCl particles have excess Cl⁻ on their surface (negative); the dye stays in solution (yellow-green).
  • After it, the particles have excess Ag⁺ (positive); the dye anion adsorbs on the surface and turns pink.
  • The precipitate should stay colloidal (large surface): avoid high salt; add dextrin. pH matters for the dye.

Comparison

MethodIndicatorTypeMedium
Mohrchromatedirectneutral to mildly basic
VolhardFe³⁺ (with SCN⁻)backacidic
Fajansadsorption dyedirectdepends on dye

Worked example (Mohr)

25.00 mL of a salt solution needs 18.20 mL of 0.1000 M AgNO₃ (after blank correction).
mol Ag⁺ = mol Cl⁻ = 0.1000 × 0.01820 = 1.820 × 10⁻³ mol.
[Cl⁻] = 1.820 × 10⁻³ / 0.02500 = 0.0728 M; as NaCl: 0.0728 × 58.44 = 4.25 g/L.

Exams usually ask

  • Describe the Mohr, Volhard and Fajans methods and their conditions.
  • Explain why Mohr's titration must not be done in acid solution.
  • Calculate halide concentration from titration data.

Common mistake

Running a Mohr titration in acid solution. Chromate becomes dichromate and the red endpoint appears late or not at all.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All CHM 235 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.