CHE 315 · Transport Phenomena I
Our notes
2 min readFlow in a circular tube
Steady, laminar, fully developed flow of a Newtonian fluid in a tube of radius R and length L under pressure drop ΔP. A cylindrical shell balance gives:
- Shear stress: τ_rz = (ΔP/2L) r (zero at the centre, largest at the wall).
- Velocity: v_z(r) = (ΔP R² / 4μL) [1 − (r/R)²], a parabola.
- v_max = ΔP R²/(4μL); v_avg = v_max/2.
- Hagen-Poiseuille law: Q = π ΔP R⁴ / (8μL)
The R⁴ means a tube of half the radius carries only a sixteenth of the flow at the same pressure drop.
Worked example: oil in a pipe
Oil: μ = 0.10 Pa s, ρ = 900 kg/m³; pipe R = 10 mm, L = 10 m, ΔP = 50 kPa.
- Q = π × 50,000 × (0.01)⁴ / (8 × 0.10 × 10) = 1.96 × 10⁻⁴ m³/s (0.71 m³ an hour).
- v_avg = Q/(πR²) = 1.96 × 10⁻⁴ / 3.14 × 10⁻⁴ = 0.625 m/s.
- Re = ρ v_avg D / μ = 900 × 0.625 × 0.02 / 0.10 = 113: laminar, so the formula applies (laminar below about 2,100).
- Wall shear stress = ΔP R/(2L) = 50,000 × 0.01 / 20 = 25 Pa.
Friction factor in laminar flow
The Fanning friction factor f = τ_w / (½ρv²). For laminar tube flow, f = 16/Re (Darcy factor f_D = 4f = 64/Re). For the example: f = 16/113 = 0.142.
Annulus
Flow between concentric tubes (radii κR and R), as in double-pipe heat exchangers and the annulus of an oil well between drill pipe and casing: the velocity is zero on both walls, with a maximum in between. The flow rate is
Q = (πΔP R⁴ / 8μL) [(1 − κ⁴) − (1 − κ²)² / ln(1/κ)]
Non-circular ducts and the hydraulic diameter
For turbulent flow (and as an estimate in laminar flow), use the hydraulic diameter D_h = 4 × (flow area) / (wetted perimeter) in the circular-pipe formulas.
- Circle: D_h = D.
- Square of side a: D_h = 4a²/(4a) = a.
- Annulus: D_h = D_outer − D_inner.
- Wide slit of gap h: D_h = 2h.
In laminar flow the constant changes with shape (in the Darcy form f_D = C/Re: 64 for a circle, 57 for a square duct, 96 for a wide slit), so exact laminar results need the duct's own solution.
Entrance length
The parabolic profile takes a distance to develop: L_e ≈ 0.06 Re D in laminar flow. In the example: 0.06 × 113 × 0.02 = 0.14 m, short compared with 10 m.
Exams usually ask
- Derive the Hagen-Poiseuille equation by a shell balance.
- Compute flow rate, average velocity, wall stress and Re; check that the flow is laminar.
- Find hydraulic diameters.
Common mistake
Using Poiseuille's law without checking Re. If Re is above about 2,100 the flow is turbulent and the pressure drop is much larger.
Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.
Read
-
Hagen–Poiseuille equation
(opens en.wikipedia.org in a new tab)
Wikipedia, Hagen–Poiseuille equation, CC BY-SA 4.0 · licence
-
Laminar flow
(opens en.wikipedia.org in a new tab)
Wikipedia, Laminar flow, CC BY-SA 4.0 · licence
Watch
We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.