Stability, not strength

A long slender column can fail by sideways buckling at a stress far below the material's yield or crushing strength. Above the critical load the straight position becomes unstable: any small disturbance grows.

Euler's critical load

For a pin-ended ideal column (straight, centrally loaded, elastic):
P_cr = π² E I / L²
Other end conditions use an effective length L_e = K L:

EndsKP_cr relative to pinned
Pinned-pinned1.01
Fixed-free (flagpole)2.01/4
Fixed-pinned0.7about 2
Fixed-fixed0.54

Buckling happens about the axis with the smallest I.

Slenderness

Radius of gyration r = √(I/A). Slenderness ratio λ = L_e/r. Euler stress σ_cr = π²E/λ². Euler is valid only when σ_cr is below the proportional limit (for mild steel, λ above about 90-100).

Worked example 1: a solid steel bar

d = 50 mm, L = 2 m, pinned ends, E = 200 GPa.

  • I = π × 50⁴/64 = 306,800 mm⁴; A = 1,963.5 mm²; r = d/4 = 12.5 mm.
  • λ = 2,000/12.5 = 160 (slender: Euler applies).
  • P_cr = π² × 200,000 × 306,800 / 2,000² = 151 kN.
  • σ_cr = 151,400/1,963.5 = 77.1 MPa, well below yield (250 MPa) ✓.

Rankine-Gordon formula

For intermediate columns, which fail by a mix of crushing and buckling:
P = σc A / (1 + a λ²)
with σc the crushing stress and a an empirical constant (mild steel about 1/7,500, pinned ends).

Worked example 2: same bar by Rankine

σc = 320 MPa, a = 1/7,500.

  • 1 + 160²/7,500 = 1 + 3.413 = 4.413.
  • P = 320 × 1,963.5 / 4.413 = 142 kN, a little below Euler (as expected: Rankine allows for crushing).

Worked example 3: fixing the ends

The same bar fixed at both ends: Euler gives 4 × 151 = 606 kN, a stress of 308 MPa, above yield. Euler is no longer valid; the column would yield first. Always check the stress.

Real columns

Real columns are slightly crooked and loaded off-centre. The secant formula and the Perry-Robertson formula (used in steel design codes) include an initial imperfection, so the capacity falls smoothly from the squash load to the Euler curve.

Exams usually ask

  • Derive Euler's formula for a pin-ended column.
  • Apply effective lengths for different end conditions.
  • Use slenderness ratio and Rankine-Gordon; explain Euler's limits.

Common mistake

Using the larger second moment of area. A column buckles about its weakest axis, so use I_min (and r_min).

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.