UNIHIVE

Study Hub UNIPORT AGR 205

AGR 205 · Agro-climatology and Meteorology

Humidity, evaporation and evapotranspiration

Vapour pressure, relative humidity and dew point, how water leaves soil and leaves, and crop water needs.

Our notes

2 min read

Ways to describe humidity

MeasureMeaning
Vapour pressure (e)Part of air pressure due to water vapour
Saturation vapour pressure (es)The most the air can hold at that temperature
Relative humidity (RH)e ÷ es × 100%
Dew pointTemperature to which air must cool to become saturated

Warm air can hold much more vapour than cool air.

Measuring humidity

The wet and dry bulb psychrometer: two thermometers, one wrapped in wet muslin. Evaporation cools the wet bulb; the drier the air, the bigger the difference. Tables give RH and dew point.

Worked example: relative humidity

At 30°C, es ≈ 4.24 kPa. The dew point is 20°C, so the actual vapour pressure equals es at 20°C ≈ 2.34 kPa.
RH = 2.34 ÷ 4.24 × 100 ≈ 55%.

Check with the formula es = 0.6108 × exp(17.27T ÷ (T + 237.3)):

  • T = 30: 17.27 × 30 ÷ 267.3 = 1.938; e^1.938 ≈ 6.95; × 0.6108 ≈ 4.24.
  • T = 20: 17.27 × 20 ÷ 257.3 = 1.342; e^1.342 ≈ 3.83; × 0.6108 ≈ 2.34.

Both values confirmed.

RH through the day

Same vapour, changing temperature: RH is highest at dawn (cool) and lowest in the afternoon (warm). Dew forms on clear nights when leaves cool below the dew point.

Evaporation and transpiration

  • Evaporation: water from soil, water bodies and wet leaves.
  • Transpiration: water lost through stomata.
  • Evapotranspiration (ET): both together from a crop field.

Faster with: more radiation, higher temperature, drier air, more wind, and more water available.

Measuring evaporation

The Class A pan: a round open pan about 121 cm across and 25 cm deep, on a wooden frame. The fall in water level each day is the pan evaporation (Epan).

From pan to crop water need

  1. Reference ET: ET₀ = Kp × Epan (Kp, the pan coefficient, often about 0.7).
  2. Crop ET: ETc = Kc × ET₀ (Kc, the crop coefficient, changes with growth stage).

Worked example

Epan = 6 mm/day, Kp = 0.7, maize at mid-season Kc = 1.2.

  • ET₀ = 0.7 × 6 = 4.2 mm/day.
  • ETc = 1.2 × 4.2 = 5.04 mm/day.

For 1 hectare: 5.04 mm = 0.00504 m × 10,000 m² = 50.4 m³ of water a day.

Check: 1 mm on 1 ha = 10 m³; 5.04 × 10 = 50.4 m³. Same.

Exams usually ask

  • Define RH and dew point, and calculate RH.
  • Explain how the evaporation pan is used to estimate crop water needs.

Common mistake

Saying RH is high in the afternoon because it feels sticky. The vapour may be high, but RH is usually lowest in the afternoon heat.

Written by the UniHive team in our own words. Spotted a mistake? Tell us on WhatsApp.

Read

Watch

We link to free material and never copy it. Every link was opened by our team before it went up; video data is a rough guide at 360p.

All AGR 205 topics

Report

Sign in to report this. It is free.

Is this your work (a lecturer, author or publisher)? Ask us to take it down.